MX-2310U MX-FX11 (FACSIMILE EXPANSION KIT) 9 – 2
C. I/F cable connection
1)
Connect the I/F cable to the MFP controller PWB, and fix the
binding band with the M3 screw included in the package.
Check to confirm that it is securely connected.
D. Shield plate and left cabinet installation
1)
Install the shield plate.
2)
Install the left cabinet.
E. Turn ON the power of the main unit
1)
Connect the power plug of the machine to the power outlet,
and turn ON the main power switch and the operation panel
power switch.
F. Destination setting
1)
Enter the SIM26-6 mode.
2)
Check to confirm that the destination setting of the machine
matches the specifications of the FAX destination. If not, the
FAX may not function properly.
G. Clear theFAX related software swithes
1)
Enter the SIM66-2 mode.
2)
Press DEST CODE button.
3)
Take a note of the corresponding destination code.
4)
Press BACK button to return to the code entry mode.
5)
Enter the destination code taken in procedure 3), and press
SET button.
6)
Press EXECUTE and YES buttons.
H. Line cable connection
1)
Connect the line cable on the line to the modular jack indicated
as “LINE.”
When connecting the line cable (to LINE or TEL), wind the line
cable two turns around the included ferrite core as shown in the fig-
ure, and connect to the modular jack which is marked with “LINE.”
After connection, perform the setting of “External telephone con-
nection" of the system setting (administrator).
2
1
1
2
2
1
2
About
10 cm