MX-2310U MX-2310U (MAIN UNIT) 2 – 7
2)
Press [EXECUTE] key.
[EXECUTE] key is highlighted and the image registration auto-
matic adjustment is started. (It takes about 15 sec to complete
the adjustment.)
3)
When the adjustment is completed, [EXECUTE] key returns to
the normal display, and the value of the adjustment result is
displayed.
The current skew level for each color is displayed on the
SKEW display section.
4)
Write down the displayed skew level.
(Meaning of the skew level value and the adjustment proce-
dure)
* If "OK" is displayed for all items of SKEW ALL_ROTATE, C,
M, and Y, there is no need to perform the adjustment.
* When "R" is displayed at the head of the value, turn the LSU
skew adjustment screw clockwise.
* When "L" is displayed at the head of the value, turn the LSU
skew adjustment screw counterclockwise.
* The turning amount of the adjustment screw corresponds to
each adjustment value. "ALL_ROTATE" indicates the num-
ber of rotations, and C, M, and Y indicate numbers of clicks.
The display value is rounded at the decimal point.
* "ALL_ROTATES" shows the number of rotations of adjust-
ments for all the adjustment screws. "C, M, and Y(SKEW)"
shows the number of adjustment click steps for each adjust-
ment screw of C, M, and Y.
Contents in ( )
MIAN, SUB: Difference from the previous adjustment value of
image registration.
Example:
If 105 for this time and 103 for the previous time,
it is displayed as 105.0 (+2.0).
SKEW, ALL_ROTATE: Judgment of the LSU skew adjustment
result. OK or NG.
PHASE: OPC drum phase adjustment value of the previous
time
Display/
Item
Content
Display
Default
NOTE
MAIN F
C
Registration adjustment value main scanning
direction (Cyan laser writing position F side)
1.0 - 199.0
100
M
Registration adjustment value main scanning
direction (Magenta laser writing position F side)
1.0 - 199.0
100
Y
Registration adjustment value main scanning
direction (Yellow laser writing position F side)
1.0 - 199.0
100
MAIN R
C
Registration adjustment value main scanning
direction (Cyan laser writing position R side)
1.0 - 199.0
100
M
Registration adjustment value main scanning
direction (Magenta laser writing position R side)
1.0 - 199.0
100
Y
Registration adjustment value main scanning
direction (Yellow laser writing position R side)
1.0 - 199.0
100
SUB
C
Registration adjustment value sub scanning direction
(Cyan drum
→
Black drum)
1.0 - 199.0
100
M
Registration adjustment value sub scanning direction
(Magenta drum
→
Black drum)
1.0 - 199.0
100
Y
Registration adjustment value sub scanning direction
(Yellow drum
→
Black drum)
1.0 - 199.0
100
SKEW
C
Print skew amount calculation result (Cyan)
-99.9 - 99.9
0
If the value is positive (+), "L" is displayed at the head of the
value. If negative (–), "R" is displayed.
If the value is in the range of –2.1 - +2.1, "(OK)" is displayed at
the bottom of the value. In the other cases, "(NG)" is displayed.
M
Print skew amount calculation result (Magenta)
-99.9 - 99.9
0
Y
Print skew amount calculation result (Yellow)
-99.9 - 99.9
0
ALL_
ROTATE
Print skew amount calculation result (Overall)
-99.9 - 99.9
0
If the value is positive (+), "L" is displayed at the head of the
value. If negative (–), "R" is displayed.
If the value is in the range of –1.6 - +1.6, "(OK)" is displayed at
the bottom of the value. In the other cases, "(NG)" is displayed.
PHASE
OPC drum phase adjustment value
1 - 8
1