LC-90Y8T
6 – 2
Table 1. Concrete flashing pattern
*2: They depend on the system. Power supply error is defined from product to product.
*3: For details, refer to ERROR STANDBY CAUSE on the adjustment process mode.
Item
Detail display
Cause
Slow flashing
Fast flashing
Inverter/Lamp system failure
Flashes once
Flashes once
Lamp error
Power PWB
failure
(Power failure, etc.)
Flashes twice
Flash once
Power supply error 2 (*2) AC_DET error
Flash twice
Power supply error 2 (*2) UR+13V error
Flash 3 times
Power supply error 2 (*2) D+3.3V error
Flash 5 times
Panel power supply error
Main PWB
failure
(Communication
failure, etc.)
Flashes 3 times
Flashes once
Initial communication error
Flashes twice
Start-up confirmation communication error
Flashes 3 times
Regular communication error
Flashes 5 times
Other communication error
r
o
r
r
e
e
r
u
t
a
r
e
p
m
e
T
e
c
n
o
s
e
h
s
a
l
F
s
e
m
it
4
s
e
h
s
a
l
F
s
r
e
h
t
O
Flashes 3 times
Notification from the main microprocessor (*3)