4. Make sure the voltage is set properly and press “OK”.
(Calibration starts.)
Figure 42
5. Click “OK”.
Figure 43
6. The initial screen returns.
4.5.4 RF performance check
1. Apply 4 V using a stabilised power supply and turn on the handset (phone).
2. Start “RF calibration & check” on SPST and click “Check”.
3. When initialisation is complete, the following message appears. Lower the stabilised power supply voltage to 3.7 V and click “OK”.
Figure 44
4. Make sure the voltage is set properly and press “OK”.
(RF performance check starts.)
Figure 45
5. The following dialogue box appears after the check. Increase the stabilised power supply voltage to 4.0 V and click “OK”.
Figure 46