Main
code
Sub
code
Contents
Details of operation
Initial
value
Set range
7
6
Intermittent aging
After completion of warmup, counting is stopped and the ready lamp is
lighted. When the copy quantity is entered and the start key is pressed,
copying is made to make the set quantity of copies. After 3 sec standby,
copying is made again to make the set quantity of copies. After that this
operation is repeated. The paper size does not matter.
1
∼
99
8
Warmup time display
Execute the simulation input with the copier side cover open, then close
the side cover, and the machine will starts warming up. Warm up time is
counted up every second and it is displayed.
9
1
Duplex motor forward
rotation operation check
<Not used>
Used to rotate the duplex motor forward for 30 sec.
2
Duplex motor reverse
rotation operation check
<Not used>
Used to rotate the duplex motor in reverse for 30 sec.
4
Duplex motor rotation
speed adjustment
<Not used>
After completion of warmup, the ready lamp is lighted and the currently
set duplex motor rotation speed set value is displayed.
When the set value is entered and the start key is pressed, the set
value is stored.
6
1
∼
13
5
Duplex motor switchback
time adjustment
<Not used>
After completion of warmup, the ready lamp is lighted and the currently
set duplex motor switchback time set value is displayed.
When the set value is entered and the start key is pressed, the set
value is stored.
50
18
∼
76
10
Toner motor operation
check
Used to operate the toner motor for 30 sec.
Note:
If this simulation is executed with the toner hopper installed, toner
is automatically supplied to the developer. Be careful of
overtoning.
14
Trouble (except for U2)
cancel
Used to cancel troubles except for U2.
16
U2 trouble cancel
Used to cancel U2 trouble.
20
1
Maintenance counter clear
Used to clear the maintenance counter.
∗
2
21
1
Maintenance cycle setting
Used to display the currently set maintenance cycle at the numbers
shown at right. When the set value is entered and the start key is
pressed, the set value is stored.
4
0
∼
6
2
Mini maintenance cycle
setting (Japan only)
<Not used>
Used to display the currently set mini maintenance cycle at the numbers
shown at right. When the set value is entered and the start key is
pressed, the set value is stored.
∗
1:
Each counter display method
To display 123456: 123 (0.75 sec)
→
Blank (0.35 sec)
→
456 (0.75 sec)
→
Blank (1.0 sec)
→
repetition
∗
2: Display after clearing each counter
000 (0.75 sec)
→
Blank (0.35 sec)
→
000 (0.75 sec)
→
Blank (1.0 sec)
→
Repetition
Key operation
Copy quantity setting: Copy quantity keys
Key operation
Duplex motor rotation speed set value: Copy quantity keys
Key operation
Duplex motor switchback time set value: Copy quantity keys
Key operation/Display
0: 2500 sheets
3: 30000 sheets
1: 5000 sheets
4: 150000 sheets
2: 15000 sheets
5: FREE (999999 sheets)
6: 10000 sheets
Key operation/Display
0: 2500 sheets
1: 5000 sheets
2: 10000 sheets
3: FREE (999999 sheets)
DM-2000