5) Gently insert the TD cartridge along the guides until it locks in
place.
Note: If dirt or dust is adhered to the TD cartridge, remove it
before installing the cartridge.
6) Close the front cover by pushing both sides with your hands and
then close the side cover by pressing the handle on the cover.
The indicator will go out.
Cautoion: When closing the covers, be sure to close the front
cover securely and then close the side cover. If the
covers are closed in the wrong order, the covers may
be damaged.
4. Removal and storage of fixing screw
1) Gently lift and pull out the paper tray until it stops.
2) Hold the paper pressure plate and turn the fixing screw in the
arrow direction.
3) Store the fixing pin and the fixing screw in the tray.
●
Store the fixing screw which was removed in the above proce-
dure 2 and the fixing screw which was removed in procedure 2
of 2.
●
Removal of protective material and fixing screw in the storage
place in the tray.
5. Changing the copy paper size in the
tray
1) Gently lift and pull out the paper tray until it stops.
2) Push the pressure plate down until it locks in place.
3) Squeeze the lock lever of the front guide and slide the front guide
to match the width of the paper.
4) Move the left guide to the appropriate slot as marked on the tray.
●
When using 11"
×
17" copy paper, store the left guide in the slot
at the left front of the paper tray.
5) Load copy paper into the tray.
6) Place the appropriate label to indicate the selected paper size into
the recess on the right front side of the paper tray.
7) Push the paper tray firmly back into the DM System.
8) Turn the power switch on.
A
B
Pressure
plate
lock
Screw
Front guide
Left guide
DM-2000
5 – 2