– 16 –
TEST 2 Soft reset
Object:
Reinitializing the unit.
Function:
Reinitializing all functions.
Operation: "ALL CLEAR" appears and the unit reinitializes all functions and then turns power on.
Leaving the test mode
After reinitializing by soft reset, the unit enters the normal power-on state.
Table 16-1 Character display
MD section
TEST 3 MD test 1
Object:
Setting the MD unit to test mode.
Function:
Setting the MD microcomputer to test mode, sending test commands which correspond to the button entry, and
displaying indication data from the microcomputer.
Operation: Power turns on and the mode is switched to MD by entering the test mode.
The test mode setting command is sent to the MD microcomputer to enter the test mode.
Button entries not in theTable 17 (page 17) are ignored.
10 characters data received from the MD microcomputer are displayed.
EJECT and LOADING are operated normally.
Disc can be loaded or unloaded forcibly by VOLUME up and down operations while MD microcomputer version is displayed
in disc chucking and while EJECT is displayed.
Leaving the test mode
Pressing the ON/STAND-BY button turns the power off normally.
No auto adjustment mode setting
While in this test mode, pressing the MEMORY/ENTER button switches the unit to the no auto adjustment operation mode
as follows.
The unit enters the no auto adjustment operation mode after the above. As normal operation, every button input is valid.
While this setting, "Center bar" should flash. The unit is in the test mode continuously.
Note:
In no auto adjustment operation mode, the mode is canceled by pressing the ON/STAND-BY button. When power turns on
again, normal power-on operation is performed.
Item
Reset operation display Operation
Sub-display 1
2
3
4
5
6
7
8
:
9
10
A
L
C
L
L
E
R
A
Sub-display
Type
Remarks
Character display