MD-MX30/MX30W
– 24 –
4. AUTO FAB adjustment mode
Step No.
Setting Method
Remarks
Display
Step 1
Test mode STOP state
The AUTO preliminary adjustment should have been completed.
[ t s m 1 A
e
]
Step 2
Press the EQUALIZER button three times. AUTO adjustment menu
[ _ A U T _ F A B _ _ ]
Step 3
Press the MD PLAY button.
The slide moves to the innermost periphery, and automatic
[F A B
_
]
Step 4
Adjustment value output
STEP 2 AUTO adjustment
[
_
_
]
Press the MD STOP button.
•
,
,
: Measurement value
5. EEPROM setting mode
A) Focus setting
Step No.
Setting Method
Display
Step 1
Test mode STOP state
[ t s m 1 A
e
]
Step 2
Press the EQUALIZER button nine times. [ E E P R O M_ S E T ]
Step 3
Press the MD PLAY button.
[ _ _ F o c u s _ _ _ ]
Step 4
Press the MD PLAY button.
[F G _ _ _ _ _ _
]
Step 5
Press the EQUALIZER button.
[F F 1 _ _ _ _ _
]
Step 6
Press the EQUALIZER button.
[F F 2 _ _ _ _ _
]
Step 7
Press the EQUALIZER button.
[F Z H L E V _ _
]
Step 8
Press the EQUALIZER button.
[F O K L E V n _
]
Step 9
Press the EQUALIZER button.
[F O K L E V f _
]
Step 10
Press the EQUALIZER button.
[F O K L P F n _
]
Step 11
Press the EQUALIZER button.
[F O K L P F f _
]
Step 12
Press the EQUALIZER button.
[W A I T f _ _ _
]
Step 13
Press the EQUALIZER button.
[D S C J G _ _ _
]
•
: Setting value
B) Spin setting
Step No.
Setting Method
Display
Step 1
Test mode STOP state
[ t s m 1 A
e
]
Step 2
Press the EQUALIZER button nine times. [ E E P R O M_ S E T ]
Step 3
Press the MD PLAY button.
[ _ _ F o c u s _ _ _ ]
Step 4
Press the EQUALIZER button.
[ _ S p i n d l e _ _ ]
Step 5
Press the MD PLAY button.
[S P G _ _ _ _ _
]
Step 6
Press the EQUALIZER button.
[S P G _ i n _ _
]
Step 7
Press the EQUALIZER button.
[S P G _ m i d _
]
Step 8
Press the EQUALIZER button.
[S P G _ o u t _
]
Step 9
Press the EQUALIZER button.
[S P 1 _ _ _ _ _
]
Step 10
Press the EQUALIZER button.
[S P 2 _ _ _ _ _
]
Step 11
Press the EQUALIZER button.
[S P 3 _ _ _ _ _
]
Step 12
Press the EQUALIZER button.
[S P 4 _ _ _ _ _
]
Step 13
Press the EQUALIZER button.
[S P 5 _ _ _ _ _
]
Step 14
Press the EQUALIZER button.
[S P D L M _ _
]
•
: Setting value
C) Tracking setting
Step No.
Setting Method
Display
Step 1
Test mode STOP state
[ t s m 1 A
e
]
Step 2
Press the EQUALIZER button nine times. [ E E P R O M_ S E T ]
Step 3
Press the MD PLAY button.
[ _ _ F o c u s _ _ _ ]
Step 4
Press the EQUALIZER button two times. [ _ T r a c k i n g _ ]
Step 5
Press the MD PLAY button.
[T G _ _ _ _ _ _
]
Step 6
Press the EQUALIZER button.
[T F 1 _ _ _ _ _
]
Step 7
Press the EQUALIZER button.
[T F 2 _ _ _ _ _
]
Step 8
Press the EQUALIZER button.
[S V C N T 4 _ _
]
Step 9
Press the EQUALIZER button.
[T R B L V o _ _
]