MD-MX30/MX30W
– 10 –
Caution on Disassembly
The disassembling the machine or assembling it after
repair, observe the following instructions to ensure safety
and keep its performance.
1. Unload the compact disc, and mini-disc, cassette tape
from machine.
2. Be sure to unplug the power cable before starting
disassembly of the machine.
3. When disassembling each section, remove the nylon
band or wire arrangement.
After servicing the unit, be sure to rearrange the leads
where they were before disassembling.
If a screw of improper length is fit to the MD mechanism.
(A screw fit the part to the mechanism chassis of MD
section), it may contact the optical pickup, impeding
normal operation. Hence, due care must be taken.
4. While repairing, pay utmost attention to static electricity
on ICs.
Figure 10-2
DISASSEMBLY
1
Top Cabinet
1. Screw ................ (A1) x7
10-2
2
Side Panel (Right,Left) 1. Screw ................ (B1) x8
10-2
3
Rear Panel
1. Socket ............... (C1) x1
10-3
2. Screw ................ (C2) x6
4
Main PWB
1. Screw ................ (D1) x9
11-1
(Note 1)
2. Flat Cable .......... (D2) x4
3. Socket ............... (D3) x3
5
Tuner PWB
1. Screw ................ (E1) x4
11-1
6
Power PWBx2
1. Socket ............... (F1) x1
11-2
2. Screw ................ (F2) x9
7
MD/CD Holder
1. Screw ................ (G1) x8
11-3
2. Flat Cable .......... (G2) x1
8
Front Panel
1. Screw ................ (H1) x4
11-4
9
Volume PWB
1. Knob .................. (J1) x1
11-5
2. Screw ................ (J2) x3
3.Nut ...................... (J3) x1
10
Display PWB
1. Knob .................. (K1) x1
11-5
2. Nut ..................... (K2) x1
3. Screw ................ (K3) x8
11
CD Servo PWB
1. Socket ............... (L1) x5
11-6
(Note 1)
2. Lug .................... (L2) x1
3. Screw ................ (L3) x3
12
MD Holder
1. Screw ................ (M1) x3
11-6
(MD Unit)
2. Screw ................ (M2) x4
13
CD Mechanism
1. Screw ................ (N1) x3
11-7
14
MD Mechanism
1. Screw ................ (P1) x8
12-1
(Note 1)
2. Flat Cable .......... (P2) x3
3. Flexible PWB .... (P3) x1
4. Socket ............... (P1) x2
STEP
REMOVAL
PROCEDURE
FIGURE
MAIN UNIT
MAIN UNIT
Figure 10-3
Note 1:
After removing the connector for the optical pickup from the
connector wrap the conductive aluminium foil around the
front end of connector so as to protect the optical pickup
from electrostatic damage.
(B1) x2
ø3 x12mm
(A1) x2
ø3 x12mm
(B1) x2
ø3 x12mm
(B1) x2
ø3 x12mm
(A1) x3
ø3 x12mm
(B1) x2
ø3 x12mm
(A1) x2
ø3 x12mm
Cabinet
Side
Panel(R)
Side Panel(L)
(C1) x1
Rear Panel
(C2) x6
ø3 x10mm
1
2
FAN MOTOR
MV01
2
1
V02
RV17
RV20
RV19
CV15
QV51
RV53
CV56
RV21
DV03
DV06
DV05
CV13
RV09
CV09
RV11
RV07
RV15
CNPV01
CNSV01
RD
RV66
RV51
CV62
RV03
RV05
CV53
RV50
LUGV01
CV07
RV01
CV61 BIV01
QV54
CV58
CV01
RV60
RV59
2 3 4 5
2 1
1
2
3
B
C
E
B C E
NSV02
11 - G,H
APLAY PWB
CHASSIS
GND
CV05
CV59
MAIN PWB-A1
Figure 10-1
Notes for servicing (For MD-MX30 only)
• This model is equipped with a fan. If you remove the fan to
service the unit, it enters the protection mode and the
power cannot be turned on by pressing the POWER
button. In such a case, follow the procedure below.
(Refer to Fig.10-1.)
1. Check whether a resistor (RV 66,39ohm,1/2W) is inserted.If
not, connect it (39ohm,1/2W).
2. Connect the patterns circled with a dotted line by soldering.
• Desolder to reassemble the unit after repairing. If you fail
to desolder, the power turns off soon because the unit
enters the protection mode when the fan rotates at a high
speed (high power).
• These steps are unnecessary to service the unit with the
fan connected.
Illustration: MD-MX30