AR-M205 SIMULATIONS 7-9
26
05
Count mode setting
When any key input is made, it is displayed on the display section. When the [START] key is pressed,
the set code data are acquired and stored to the count mode set variable and in the EEPROM, and
the machine goes into the sub code input standby mode. However, if the [START] key is pressed
outside the set range, it is not assured. At that time, when the [Interrupt] key is pressed, the data are
not rewritten and the machine goes into the sub code input standby mode. When the [CA] key is
pressed, the simulation is terminated without rewriting the data.
06
Destination setting
When this simulation is executed, the current set destination code number is displayed. Enter the
desired code number of the destination and press the [START] key to set the destination.
If this setting is changed, SIM46-19 setting is also changed accordingly.
(The paper size is also changed: AB series is changed to A4, and Inch series to Letter.
The AE limit setup is set to the default.
When the destination is changed (from Japan to EX Japan or from EX Japan to Japan),
the maintenance cycle is also set to the default accordingly.)
07
Machine condition check (CPM)
When this simulation is executed, the current setting of the machine is displayed.
18
Toner save mode setting
Used to set ON/OFF of the toner save mode.
*
The toner save mode of the user program is also changed accordingly.
30
CE mark conformity control ON/
OFF
When this simulation is executed, the current set code number of CE mark conformity is displayed.
Enter the desired code number of CE mark conformity and press the [START] key to set the code
number.
31
Auditor mode exclusive setup
Used to set whether the manual fed tray can be used or not when the auditor mode is set to the coin
vendor mode.
*
When this is set to "Exclusive setup ON," if the auditor is set to the coin vendor mode and the
standard tray is set to the manual feed tray, the standard tray must be set to the main cassette.
36
Cancel of stop at maintenance life
over
Used to set stop at maintenance life over.
37
Cancel of stop at developer life
over
When this simulation is executed, the current set code number is displayed. Enter the desired code
number and press the [START] key to set the code number. The machine goes into the sub code
input state.
Main
code
Sub
code
Contents
Details of operation
[*1 : Total counter / Developer counter *2 : maintenance counter]
0:
1:
2:
3:
*1= Double count
*1= Single count
*1= Double count
*1= Single count
*2= Double count
*2 = Double count
*2= Single count
*2= Single count
Code number
Destination
0
1
2
3
4
5
6
Japan AB series
Inch series
EX Japan AB series
EX Japan inch series
EX Japan AB series (FC)
China (EX Japan AB China paper support)
Taiwan (EX Japan AB China paper support)
7-seg display
Meaning (CPM information)
15
16
20
15CPM
16CPM
20CPM
Code number
Setting
0
1
Toner save OFF
Toner save ON
Code number
Setting
0
1
CE mark conformity control OFF *Default for 100V system
CE mark conformity control ON
Code number
Setting
0
1
Exclusive setup OFF (Manual paper feed allowed)
Exclusive setup ON (Manual paper fed inhibited)
Code number
Setting
0
1
Stop at maintenance life over
Cancel of stop at maintenance life over * Default
Code number
Setting
0
1
Stop at developer life over
Cancel of stop at developer life over
Summary of Contents for AR-M160