AR-M205 SIMULATIONS 7-7
22
07
Mini maintenance preset display
(Valid only when the destination is
set to Japan AB series)
The mini maintenance cycle data is acquired and displayed on the 7-seg display.
When the [Interrupt] key is pressed, the machine goes into the sub code input standby mode.
When the [CA] key is pressed, the simulation is terminated.
08
SPF counter display
The SPF counter value is displayed.
09
Paper feed counter display
The counter value of the selected paper feed section is acquired from each variable, the data is
displayed on the 7-seg display according to the regulations. When this simulation is executed, the
value of the first cassette is displayed first. Press the tray select key to select the paper feed tray.
When the [Interrupt] key is pressed, the machine goes into the sub code input standby mode.
When the [CA] key is pressed, the simulation is terminated.
12
Drum counter display
The drum counter and the drum rotating time are displayed.
To change the display mode, press the [Mode select] key.
13
CRUM destination display
When this simulation is executed, the CRUM destination set (written) in the CRUM chip is displayed.
This simulation is valid only for the models where the CRUM is valid.
14
P-ROM version display
The P-ROM version is displayed on the copy quantity display. The main code and the sub code are
alternatively displayed by 2 digits. The display interval is same as that of the counter display.
By pressing the fixed magnification ratio key, each version display is switched.
15
Trouble memory display
The trouble codes up to the latest one are acquired from the trouble memory data.
Every time when the magnification ratio display is pressed, the main code of the trouble is displayed
on the 1st ~ 2nd digit.
*
The latest 20 troubles are stored in the memory.
The 3rd digit indicates the trouble history code, "A" ~ "J" (meaning of 1 ~ 10).
After "J" is displayed, "A" ~ "J" blinks. (Meaning of 11 ~ 20)
After "J" blinks (meaning of 20), "A" ~ "J" is lighted. (Returns to 1.)
When the [START] key is pressed, the sub code is displayed.
When the [Interrupt] key is pressed, the machine goes into the sub code input standby mode.
When the [CA] key is pressed, the simulation is terminated.
*
Note that when the history code blinks, the trouble code and the sub code do not blink.
16
Duplex print counter display
Data is acquired from the duplex print counter variable, and is displayed.
When the [Interrupt] key is pressed, the machine goes into the sub code input standby mode.
When the [CA] key is pressed, the simulation is terminated.
17
Copy counter display
The copy counter value is displayed. When the [Interrupt] key is pressed, the machine goes into the
sub code input standby mode. When the [CA] key is pressed, the simulation is terminated.
18
Printer counter display
The printer counter value is displayed. When the [Interrupt] key is pressed, the machine goes into the
sub code input standby mode. When the [CA] key is pressed, the simulation is terminated.
19
Scanner mode counter display
The scanner mode counter value is displayed. When the [Interrupt] key is pressed, the machine goes
into the sub code input standby mode. When the [CA] key is pressed, the simulation is terminated.
21
Scanner counter display
The scanner counter value is displayed. When the [Interrupt] key is pressed, the machine goes into
the sub code input standby mode. When the [CA] key is pressed, the simulation is terminated.
22
SPF jam counter display
The SPF jam counter value is displayed. When the [Interrupt] key is pressed, the machine goes into
the sub code input standby mode. When the [CA] key is pressed, the simulation is terminated.
24
01
Jam total counter clear
When the [START] key is pressed, the jam total count value is reset to zero, and zero is displayed.
02
Trouble memory clear
The trouble memory and the EEPROM trouble history data are cleared and "000" is displayed on the
7-seg display. When the [Interrupt] key is pressed, the machine goes into the sub code input standby
mode. When the [CA] key is pressed, the simulation is terminated.
04
SPF counter clear
When the [START] key is pressed, the SPF count value is reset to zero and displayed on the 7-seg
display. When the [Interrupt] key is pressed, the machine goes into the sub code input standby mode.
When the [CA] key is pressed, the simulation is terminated.
05
Duplex print counter clear
The duplex print count data is cleared, and zero is displayed on the 7-seg display.
When the [Interrupt] key is pressed, the machine goes into the sub code input standby mode.
When the [CA] key is pressed, the simulation is terminated.
06
Paper feed counter clear
The paper feed counter data of each paper feed section is cleared, and "000" is displayed on the 7-
seg display. When the [Interrupt] key is pressed, the machine goes into the sub code input standby
mode. When the [CA] key is pressed, the simulation is terminated.
Main
code
Sub
code
Contents
Details of operation
Display lamp
AE mode lamp
TEXT mode lamp
Display mode
Drum counter
Drum rotating time
7-seg display
Meaning (CRUM destination)
7-seg display
Meaning (CRUM destination)
00
01
02
03
Not set yet
BTA-A
BTA-B
BTA-C
04
99
12
BTA-E
Conversion
AL series
Display lamp (AB series)
Display lamp (Inch series)
Displayed version
141%
115%
141%
121%
Machine program
IMC program
!"#$