AR-M205 SIMULATIONS 7-10
26
38
Cancel of stop at drum life over
When this simulation is executed, the current set code number is displayed. Enter the desired code
number and press the [START] key to set the code number.
39
Memory capacity check
When this simulation is executed, the current memory capacity is displayed.
42
Transfer ON/OFF timing control
setting
When this simulation is executed, the current setting value of transfer ON timing is displayed.
Enter a set value and press the [START] key to set the entered value, and the machine will go into
the sub code input standby mode.
When the [Mode select] key is pressed, the ON timing setting and the OFF timing setting are
alternatively selected. At that time, the setting is saved and written into the EEPROM.
•Setting range: 1 ~ 99
When the setting value is increased by 1, time is increased by 2ms.
•The default, 50, of transfer ON timing means "344ms passed from PS release."
The default, 50, of transfer OFF timing means "304ms passed from P-IN OFF."
43
Side void amount setting
Used to set the side void amount on the both sides.
Enter a set value with the 10-key and press the [START] key, and the entered value will be saved and
the machine will go into the sub code input standby mode.
The setting range is 0 ~ 10. When the set value is increased by 1, the void amount is increased by
0.5mm. The default is 3 (= 1.5mm).
To select the setting mode, press the [Exposure mode select] key. The set value of the selected
mode is displayed on the copy quantity display. At that time, the set value is also saved.
*
When the setting value is increased by 1, time is increased by 0.5ms.
51
Copy temporary stop function
setting
When any key is pressed, it is displayed on the display section. When the [START] key is pressed,
the set code data is acquired and stored to the setting variable of sort/group copy temporary stop
function and to the EEPROM. The machine goes into the sub code input standby mode.
When the [Interrupt] key is pressed at that time, the machine goes into the sub code input standby
mode without rewriting the data. When the [CA] key is pressed, the simulation mode is terminated
without rewriting the data.
*
When this is set to "Stop," temporary stop is made for every 250 copies in one copy job.
30
01
Paper sensor status display
The paper sensor status is displayed with the lamps on the operation panel.
*
When each sensor detects paper, the corresponding lamp turns on.
42
01
Developing counter clear
The developer counter data in the EEPROM is cleared and 0 is displayed on the 7-seg display.
When the [Interrupt] key is pressed at that time, the machine goes into the sub code input standby
mode. When the [CA] key is pressed, the simulation mode is terminated.
Main
code
Sub
code
Contents
Details of operation
Code number
Setting
0
1
Stop at drum life over
Cancel of stop at drum life over
7-seg display
Meaning (Memory capacity)
16
32
16MByte
32MByte
Display lamp
Setting mode
Default
AE mode lamp
TEXT mode lamp
Transfer ON timing
Transfer OFF timing
50
50
Display lamp
Setting mode
AE mode lamp
TEXT mode lamp
Side void amount (Right)
Side void amount (Left)
Code number
Setting
0
1
Not stop
Stop * Default
Display lamp
Sensor name
Developer lamp
Machine jam lamp
Toner lamp
Manual paper feed lamp
No. 1 cassette lamp
No. 2 cassette lamp
No. 3 cassette lamp
No. 4 cassette lamp
Tray jam lamp 1
Tray jam lamp 2
Paper empty lamp
Paper exit sensor
Duplex sensor
Paper entry sensor
Manual feed paper empty sensor
No. 1 tray paper empty sensor
No. 2 tray paper empty sensor
No. 3 tray paper empty sensor
No. 4 tray paper empty sensor
No. 2 tray paper feed sensor
No. 3 tray paper feed sensor
No. 4 tray paper feed sensor
!"#$