Main
code
Sub
code
Contents
Details of operation
Initial
value
Set range
26
1
Option switch display
Used to display the installed option on the operation panel. (The LED
corresponding to the installed option is lighted.)
3
Auditor setting
Used to display the current auditor setting with the numbers at right.
After entering the set value, press the start key, and the set value is
stored.
0
0
∼
2
5
Counter mode setting
Used to set the print counter mode in A3 or 11"
×
17".
Used to display the currently set counter value with the numbers at right.
After entering the set value, press the start key, and the set value is
stored.
0
0
∼
3
Key
operation
Display
Display
select:
Magnification
ratio display
key
<Lighting with an option installed>
When “A” is displayed:
Shifter: Paper empty LED
Job separator: JAM LED
SPF: SPF select LED
RSPF: SPF JAM LED
Duplex mode: Main cassette select LED
Simplex mode: Multi manual paper feed select LED
MCU JMPER1: Top of the magnification ratio display
MCU JMPER2: 2nd of the magnification ratio display
MCU JMPER3: 3rd of the magnification ratio display
MCU JMPER7: 4th of the magnification ratio display
MCU JMPER7: 5th of the magnification ratio display
MCU JMPER7: 6th of the magnification ratio display
MCU JMPER7: 7th of the magnification ratio display
MCU JMPER8: Bottom of the magnification ratio
display
When “b” is displayed:
Cassette (2nd step): No. 2 cassette select LED
Cassette (3rd step): No. 3 cassette select LED
Cassette (4th step): No. 4 cassette select LED
Memory installed: Paper empty LED
FAX: JAM LED
Printer: Main body JAM LED
ERDH: Main cassette select LED
16CPM: SPF JAM LED
20CPM: SPF select LED
Document sensor: Auto paper select LED
Key operation/Display
0: Built-in auditor
1: Coin vendor
2: Others
Key operation/Display
0: Total/Developer = 2 counts
Maintenance = 2 counts
1: Total/Developer = 1 count
Maintenance = 2 counts
2: Total/Developer = 2 counts
Maintenance = 1 count
3: Total/Developer = 1 count
Maintenance = 1 count
AR-162 SIMULATIONS – 7