<Adjustment specification>
Note: A judgement must be made with 200mm width, and must not
be made with 100mm width.
Mode
Specification
SIM
Set value
Set range
Main scanning
direction
magnification
ratio
At normal:
±
1.0%
SIM
48-1
Add 1:
0.1% increase
Reduce 1:
0.1% decrease
1 ~ 99
•
Error in the auto correction mode
Display
Content
Major cause
Copy
quantity
display "– –"
The correction
value calculated is
over 5%.
•
Improper position of
reference width line of
the reference white plate
•
Improper installation of
CCD unit
Paper jam
lamp ON
Reference line
scanning error
•
Defective CCD
•
No reference white plate
*
When SIM 48-01 (AE) is executed, the main scanning direction
magnification ratio is automatically set. Therefore, the main scan-
ning direction magnification ratio adjustment previously described
in 5) must be made again.
(6) Sub scanning direction (scanning direction)
magnification ratio adjustment (SIM 48-2, SIM 48-5)
a. OC mode in copying
Note:
•
Before performing this adjustment, be sure to check that the
CCD unit is properly installed.
1) Put a scale on the original table as shown below, and make a
normal (100%) copy.
2) Compare the scale image and the actual image. If necessary,
perform the following adjustment procedures.
3) Execute SIM 48-2.
4) After warmup, shading is performed and the current set value of
the sub scanning direction magnification ratio is displayed on the
display section in 2 digits.
5) Enter the set value and press the start key.
The set value is stored and a copy is made.
<Adjustment specification>
Mode
Specification
SIM
Set value
Set range
Sub scanning
direction
magnification
ratio
(OC mode)
Normal
±
1.0%
SIM
48-2
Add 1:
0.1% increase
Reduce 1:
0.1% decrease
1 ~ 99
b. RSPF sub scanning direction magnification ratio
Note:
•
Before performing this adjustment, be sure to check that the
CCD unit is properly installed.
•
Before performing this adjustment, the OC mode adjust-
ment in copying must be completed.
1) Put a scale on the original table as shown below, and make a
normal (100%) copy to make a test chart.
Note: Since the printed copy is used as a test chart, put the scale
in parallel with the edge lines.
2) Set the test chart on the SPF and make a normal (100%) copy.
3) Compare the scale image and the actual image. If necessary,
perform the following adjustment procedures.
4) Execute SIM 48-5.
5) After warmup, shading is performed.
The auto density lamp lights up and the current front surface sub
scanning direction magnification ratio correction value is displayed
in two digits on the display section.
6) Enter the set value and press the start key.
The set value is stored and a copy is made.
7) Change the mode from the duplex original mode to the simplex
original mode.
"MANUAL" lamp lights up and the current back surface sub scan-
ning direction magnification ratio is displayed in two digits on the
display section.
8) Enter the set value and press the start key.
The set value is stored and a copy is made.
<Adjustment specification>
Mode
Specification
SIM
Set value
Set range
Sub scanning
direction
magnification
ratio
(SPF mode)
Normal
±
1.0%
SIM
48-5
Add 1:
0.1% increase
Reduce 1:
0.1% decrease
1 ~ 99
(7) Off center adjustment (SIM 50-13, SIM 50-16)
a. OC mode
Note:
•
The operation of SIM 50-13 is the same as that of SIM
48-01 (Photo LED ON)
1) Make a test chart as shown below and set it so that its center line
is fit with the original guide center mark.
*
To make a test chart, draw a line on A3 or 11" x 17" paper at
the center in the paper transport direction.
2) Make a normal copy from the manual paper feed tray, and com-
pare the copy and the test chart.
If necessary, perform the following adjustment procedures.
3) Execute SIM 50-13.
4) After warmup, shading is performed and the current set value of
the off center adjustment is displayed on the display section in 2
digits.
5) Enter the set value and press the start key.
The set value is stored and a copy is made.
<Adjustment specification>
Mode
Specification
SIM
Set value
Set range
Original
off center
mode
(OC mode)
Single:
Center
±
2.0mm
SIM
50-13
Add 1:
0.1mm shift to
R side
Reduce 1:
0.1mm shift to
L side
1 ~ 99
Duplex:
Center
±
2.5mm
Center
Original guide
Copy paper
(A3 or 17" x 11")
AR-162 [6] ADJUSTMENT 11/1/2000
AR-162 ADJUSTMENTS – 8