AL-2051 SIMULATION, TROUBLE CODES 10 - 13
26
42
Transfer ON timing control
setup
[Function]
[Operation]
Main
code
Sub
code
Contents
Details of function/operation
When this simulation is executed, the currently set code number is displayed.
Enter the code number and press the [START] key, and the setting will be changed. (For any
number different from the following ones, the default time is automatically set.)
The adjustment can be made individually for each of the following modes.
<Paper lead edge adjustment table>
Note 1
:
The default code ‘11
’
for the transfer ON timing indicates a lapse of 236ms from PS release.
Note 2
:
If the code “0” is selected, the setting is the same as the default setting ‘11
’
.
Note 3
:
The transfer ON timing can be adjusted in increments/decrements of 2ms within the range of
236ms±20ms.
<Front/back surface of paper rear edge adjustment table>
* The default "50" of the transfer OFF timing indicates "210msec passed from PPD1OFF."
* The transfer OFF timing can be adjusted to 210msec ± 2ms.
Mode
Display item
Default
Setting range
Front surface paper lead edge
F-REAR
11
0 - 21
Front surface paper rear edge
F-END
50
1 - 99
Back surface paper lead edge
B-REAR
11
0 - 21
Back surface paper rear edge
B-END
50
1 - 99
Code
Setting
Remark
0
0 msec
1
–20 msec
. . .
. . .
10
–2 msec
11
0 msec
Default
12
2 msec
. . .
. . .
21
20 msec
Code
Setting
Remark
1
–98 msec
. . .
. . .
49
–2 msec
50
0 msec
Default
51
+2 msec
. . .
. . .
99
+98 msec
1) Initial display
<Front surface lead edge setting>
2) [
] [
] key
:
Mode selection
3) [Numeric] key
:
Value entry
4) [ENTER]/[START] key
:
Settles the entered value. The display is
shifted to the sub code input standby
menu.
26-
4
2
TC
O
N
T
IMING
F-
REAR
11
(
0
-2
1
)
26-
4
2
TC
O
N
T
IMING
F-
E
N
D
5
0
(
1
-99 )
26-
4
2
TC
O
N
T
IMING
F-
E
N
D
5
1
(
1