User’s Guide
HRP/S
-
31
-
HS
Tensioning and changing the filament
11
11.3
CHANGING
1.
Turn the filament to the lowest position. (Only for bottom heating).
2.
Unscrew socket head screw in the wire pin on the right.
(Use socket screw key
no. 1½
).
3.
On the left side slide the expanding pin with the spring out of
the pin block.
4.
Slide the spring off the expanding pin.
5.
Unscrew the expanding pin from the connection screw (incl.
connection wire).
6.
Remove filament from the expanding pin and the wire pin.
7.
Slide a new filament into the expanding pin and make sure that
the eye is pulled well into the pin.
8.
Screw the expanding pin onto the connection screw (incl. connection wire) and
attach firmly.
Take care not to damage the expanding pin. Tightening firmly by hand is sufficient.
2
5
Connection screw
Expanding pin
7
Eye
Pin block