User’s Guide
HRP/S
-
29
-
HS
Maintenance
10
4.
The water separator is now visible. If there is water in the glass
holder, it should be drained off (see
§10.4.2
).
10.4.2
Emptying
1.
Disengage the air connection
The top frame will lower slowly.
2.
Remove the right-hand frame plate on the front of the machine
3.
The drain nipple at the bottom of the water separator can now
be reached through the hole in the base plate.
4.
Hold a container under the nipple and slowly open the nipple. All
the water will then run out of the glass holder.
5.
Close the drain nipple by hand.
6.
Screw the right hand frame plate back in position.
7.
Switch the machine on again as described in Section
7
.
Glass holder
Drain nipple
Water separator
Water separator
4
3