User’s Guide
HRP/S
-
14
-
HS
Operation
7.1
PREPARATION
1.
Check that the air pressure is connected.
2.
Clear the working surface.
3.
Check that all the heating elements are connected to the
control units.
4.
Check that no scraps of material remain in the reflectors.
5.
Check that all the upper heating elements and pressure
bars are firmly attached to the top frame.
6.
Turn off all regulating units.
7.2
SWITCHING ON HEATING ELEMENTS
Each heating element can be switched on and controlled
individually.
1.
Switch on control unit with switch
H
. (see 5.5, page 12)
7.3
SETTING TEMPERATURE
The temperature of the filament can be set using the
temperature control.
1.
When turning on the on/off switch, the display will show the
value that was last saved (keeping the machine on a certain
value for >20 seconds will make it remember this value).
2.
Press the right button (arrow up) to increase the value, up to
99 (keeping this pressed in will make the value cycle much
faster)
3.
Press the left button (arrow down) to decrease the value,
down to 00 (keeping this pressed in will make the value cycle
much faster)
4.
Press both buttons at the same time to go directly to 00.
Doing this also resets the machine.
7