background image

GB

appendice

page 

5

I

D

F

E

2.3 Lockng and unlocking the mechanism

Giotto fixtures have a mechanical locking
system for the moving parts.
Moving head and yoke must be locked
every time the fixture is transported,
using either a suitable flightcase or the
original packaging, which have suitable
shock-resistant support devices.

ALWAYS remember to unlock the mecha-
nism BEFORE switching the fixture on!!!

Locking and unlocking procedure is car-
ried out by turning the two knobs on the
yoke, following the printed instructions.

2.4 Replacing dichroic filters

As well as the CMY mixing system, the Giotto also has a wheel fitted with 5 high quality selected
dichroic filters (ø51.8mm). If operators require to replace these with other colours, once the
cover has been opened (see chapter 2.1) find the
filter wheel, open it extremely carefully, remove
the old filter and fit the replacement.
This procedure must be carried out by qualified
personnel with the fixture switched off and after
waiting at least 30 minutes for the internal parts
of the moving head to cool down.

2.5 Periodic cleaning and checks

The fixture should be cleaned every 300 approximately (or whenever necessary) using compres-
sed air to remove dust which may have built up.
The paint used can be cleaned with alcohol or similar products: in this case, always use a non-
abrasive cloth. Make absolutely certain to avoid damaging the display by pressing too hard on it.
To ensure perfect fixture efficiency, an overall check every 600 running hours is advisable.

Electrical and mechanical parts must be checked by qualified technical personnel.

u n

lo

ck

lo

c k

remove lock
before turning
on the
fixture

togliere il
blocco prima
di accendere
il proiettore

u n

lo

ck

lo

c k

remove lock before turning on the fixture

togliere il blocco prima di accendere il proiettore

u n

lo

ck

lo

c k

remove lock
before turning
on the
fixture

togliere il
blocco prima
di accendere
il proiettore

u n

lo

ck

lo

c k

remove lock before turning on the fixture

togliere il blocco prima di accendere il proiettore

Summary of Contents for Giotto WASH 1200

Page 1: ...rel 1 00 Giotto professional moving head wash luminaire WASH WASH 1200 user manual...

Page 2: ...e following conditions In places subject to excessive humidity In places subject to vibrations or bumps In places with a temperature of more than 45 C or less than 2 C Protect the fixture from excessi...

Page 3: ...8 Chapter 3 8 Lamp ignition meter 8 Chapter 3 9 Fixture elapsed time meter 9 Chapter 3 10 Input signal 9 Chapter 3 11 Pan Tilt resolution 9 Chapter 3 12 Remote lamp control 9 Chapter 3 13 Remote fixt...

Page 4: ...ility up to SGM s usual standards The smart lines and optimisation of the outer structure to ensure user friendliness enable the fix ture to be installed in absolutely any position and any maintenance...

Page 5: ...se burns wait for at least 30 minutes after switching the unit off Once the lamp has been fitted in the lampholder make certain that it has been fitted perfectly and then lock the flange back in place...

Page 6: ...lified personnel with the fixture switched off and after waiting at least 30 minutes for the internal parts of the moving head to cool down 2 5 Periodic cleaning and checks The fixture should be clean...

Page 7: ...nly the controls sent to that specific unit To address the fixture press ENTER will appear on the display with the word Addr flashing The Up Down keys now allow the value required to be entered Press...

Page 8: ...enu with Up Down or will appear To change the direction of rotation press ENTER and then change from Norm to Rev or vice versa with the Up Down keys then press ENTER to confirm the new choice 3 5 Limi...

Page 9: ...r or UP to restore the value Undo function 3 8 Lamp ignition meter Giotto s microcomputer stores various data in its memory including those relative to the number of times the lamp has been switched o...

Page 10: ...the controller or desk to be used 3 12 Remote lamp switching Operators can decide if the lamp has to be switched on from the controller or automatically To access to this function scroll with Up Down...

Page 11: ...Down then press ENTER again 3 15 Display reading angle When the fixture is hung head downwards from a structure the display messages can be rota ted through 180 thus facilitating access to the program...

Page 12: ...be used over the colours created by the CMY system 4 4 Ch 6 CMY system Cyan Wheel This channel is part of the CMY colour mixing group which creates colours using an additive method i e superimposing...

Page 13: ...00 4 8 Ch 10 Shutter and Strobe This channel controls the opening and closing of the shutter and the Giotto s strobe effect The strobe is enabled according to the values shown on the table alongside 4...

Page 14: ...n alongside When the value set is between 251 and 255 the time depends on the cross fade time set on the controller 4 11 Ch 13 Remote lamp switching and reset When the operator enables the remote lamp...

Page 15: ...cod M001190 Via Pio La Torre 1 61010 TAVULLIA PS ITALY Tel 39 0721476477 Fax 39 0721476170 www sgm it info sgm it...