background image

GB

appendice

page 

9

I

D

F

E

3.10 Input signal

This function allows to choose which type of input signal is to be used, choosing between DMX
512 and RS-232.

For access to this function, scr oll with Up/Down until 

or

appears. Then press ENTER, use Up/Down to select the required value, then

press ENTER again.

3.11 Pan/Tilt resolution

This function allows to set the resolution of the required movement at either 16 or 8 bits. As men-
tioned in chapters 3.3 and 3.5, these differ for the number of steps into which the mobile head’s
movement is divided.
In 16-bit (SGM) mode, the 540° Pan and 270° Tilt are divided into 65,536 steps, ensuring very
smooth precise movement. In 5-bit (STD) mode, there are 256 steps, which nevertheless give
precise movement.

To access this function, scroll with Up/Down until 

or 

appears. 
Then press ENTER, use Up/Down to select the required value, then press ENTER again.
Remember to use the correct parameters in the configuration of the fixture in the Soft Patch of
the controller or desk to be used.

3.12 Remote lamp switching

Operators can decide if the lamp has to be switched on from the controller or automatically.

To access to this function, scr oll with Up/Down until 

or

appears, where EN means enabled (active, i.e. via remote control) and DS

disabled (not active, therefore automatic). Then press ENTER, use Up/Down to select the value
required, then press ENTER again.
Remember to use the correct parameters in the configuration of the fixture in the Soft Patch of
the controller or desk to be used.

3.13 Remote fixture reset

Operators can decide when the Giotto can be reset from the controller or only run automatically
when the fixture is switched on.

For access to this function, scr oll with Up/Down until 

or

appears, where EN stands for enabled (active, therefore under remote con-

trol) and DS for disabled (not active, so automatic). Then press ENTER, use Up/Down to select
the required value, then press ENTER. again
Remember to use the correct parameters in the configuration of the fixture in the software Patch
of the controller or desk which is to be used.

RST_CTR=DS

RST_CTR=EN

LMP_CTR=DS

LMP_CTR=EN

IN_MOD=STD

IN_MOD=SGM

SIGN=RS232

SIGN=DMX

Summary of Contents for Giotto WASH 1200

Page 1: ...rel 1 00 Giotto professional moving head wash luminaire WASH WASH 1200 user manual...

Page 2: ...e following conditions In places subject to excessive humidity In places subject to vibrations or bumps In places with a temperature of more than 45 C or less than 2 C Protect the fixture from excessi...

Page 3: ...8 Chapter 3 8 Lamp ignition meter 8 Chapter 3 9 Fixture elapsed time meter 9 Chapter 3 10 Input signal 9 Chapter 3 11 Pan Tilt resolution 9 Chapter 3 12 Remote lamp control 9 Chapter 3 13 Remote fixt...

Page 4: ...ility up to SGM s usual standards The smart lines and optimisation of the outer structure to ensure user friendliness enable the fix ture to be installed in absolutely any position and any maintenance...

Page 5: ...se burns wait for at least 30 minutes after switching the unit off Once the lamp has been fitted in the lampholder make certain that it has been fitted perfectly and then lock the flange back in place...

Page 6: ...lified personnel with the fixture switched off and after waiting at least 30 minutes for the internal parts of the moving head to cool down 2 5 Periodic cleaning and checks The fixture should be clean...

Page 7: ...nly the controls sent to that specific unit To address the fixture press ENTER will appear on the display with the word Addr flashing The Up Down keys now allow the value required to be entered Press...

Page 8: ...enu with Up Down or will appear To change the direction of rotation press ENTER and then change from Norm to Rev or vice versa with the Up Down keys then press ENTER to confirm the new choice 3 5 Limi...

Page 9: ...r or UP to restore the value Undo function 3 8 Lamp ignition meter Giotto s microcomputer stores various data in its memory including those relative to the number of times the lamp has been switched o...

Page 10: ...the controller or desk to be used 3 12 Remote lamp switching Operators can decide if the lamp has to be switched on from the controller or automatically To access to this function scroll with Up Down...

Page 11: ...Down then press ENTER again 3 15 Display reading angle When the fixture is hung head downwards from a structure the display messages can be rota ted through 180 thus facilitating access to the program...

Page 12: ...be used over the colours created by the CMY system 4 4 Ch 6 CMY system Cyan Wheel This channel is part of the CMY colour mixing group which creates colours using an additive method i e superimposing...

Page 13: ...00 4 8 Ch 10 Shutter and Strobe This channel controls the opening and closing of the shutter and the Giotto s strobe effect The strobe is enabled according to the values shown on the table alongside 4...

Page 14: ...n alongside When the value set is between 251 and 255 the time depends on the cross fade time set on the controller 4 11 Ch 13 Remote lamp switching and reset When the operator enables the remote lamp...

Page 15: ...cod M001190 Via Pio La Torre 1 61010 TAVULLIA PS ITALY Tel 39 0721476477 Fax 39 0721476170 www sgm it info sgm it...

Reviews: