15
D
Giotto spot r
el.1.00
E
F
E
EN
N
I
Appendix
Menu Options
Description
(Default configurations are shown in bold text
)
Addr=xxx
Range 001-487
Addressing the fixture
Pmove
NORM
Normal control of Pan from left to right
.
REV
Control of Pan inverted - from right to left.
PP_min
Range 000-540
Sets Pan starting angle.
Default Configuration = 000 degrees
PP_max
Range 000-540
Range 000-540 Sets Pan ending angle.
Default Configuration = 000 degrees
NORM
Normal control of Tilt from up to down.
.
Tmove
REV
Control of Tilt inverted, from bottom to top.
TP_min
Range 000-270
Range 000-270 Set Tilt starting angle.
Default Configuration = 000 degrees
TP_max
Range 000-270
Range 000-270 Sets Tilt ending angle
Default Configuration = 000 degrees
ON
Pan is controlled by Tilt commands and vice versa
Swap
OFF
Normal control of Pan and Tilt
Lmp_H
Read-only menu. Records the elapsed time of the lamp.
Can be reset.
Lmp_st
Read-only menu. Records the number of lamp strikes.
Can be reset.
SCN_h
Read-only menu. Records total fixture operating time.
SIGN
DMX
Signal DMX selected
RS-232
Signal RS-232 selected
SMD
16 bit
8 bit
Allows to select movement resolution.
Default configuration = 16-bit
EN
Remote control of lamp ignition enabled.
LMP_ctr
DS
Remote control of lamp ignition disabled.
EN
Remote control of reset enabled.
RST_ctr
DS
Remote control of reset disabled.
Speed
100% - 92%
84% - 76%
Possibility of slowing the maximum speed of PAN and TILT movement.
Default configuration = 100%
Accel
Fast
Optimizes speed performance.
Slow
Optimizes performance for the smooth movement
100-53-40-27-20-13-
6-0 (%)
Allows to regulate the brightness of the display.
Default configuration=40%
DsplFlip
Inverts the reading position of the display.
Used according to the position of the fixture.
DMXdly
Range 8-998 sec
It's possible to decide for how many seconds the fixture's last operating
status must be held when there's no DMX signal (default =20sec.).
ON
Energy saving enabled
SLLF
OFF
Energy saving disabled
TEST
Reserved
Giotto
1.4
Read-only menu giving information on the software version
supported by the fixture.
UNL
it maintains always the last condition of job independently from how
much time lacks the dmx
Bright