background image

14

Giotto spot r

el.1.00

3.0 - “Control” microcomputer 

Giotto Spot 1200 is equipped with a microcomputer which allows to customize the fixture to suite the type of installation.
In fact, it's possible to assign the start address; obtain information regarding lamp life and fixture operation time; run test
programs to check correct fixture operation and customize some parameters.

3.1- Navigating in the menu

When it's switched on, the fixture runs a start-up reset procedure and the display indicates if there's an input signal or not.

The 3 keys under the display are for selecting and using the various submenus which make up the main menu.

- UP/DOWN 

keys: used to scroll the various items in the menu. In the selected menu, used to change the required para-

meters.

- ENTER key: 

used to access to the selected menu and, once the necessary changes have been made, is used to confirm

them.

E010485 - 

13

1

1

Giotto 1.4

E010485 - 1.

3

Giotto 1.4

E010485 - 

13

2

2

Accel

Summary of Contents for Giotto spot 1200

Page 1: ...Gi ot to s pot 12 00 P r o f e s s i o n a l M o v i n g h e a d User s Manual rel 1 00...

Page 2: ...r supply to the fixture immediately In the event of serious operating problems stop using the fixture immediately and either contact the nearest SGM sales point for a check or contact the manufacturer...

Page 3: ...verting Pan Tilt 18 3 6 Lamp elapsed time meter 18 3 61 Resetting the lamp s elapsed time meter 18 3 7 Lamp strike counter 18 3 71 Resetting the lamp s strike counter 19 3 8 Fixture operating time met...

Page 4: ...in fact make it one of the best fixtures on the market today as far as power and luminosity are concerned The lamp and electronics are powered by an electronic ballast entirely designed by the SGM Re...

Page 5: ...n the event of accidental head movement invertible Pan Tilt movement Adjustable Pan Tilt offset Adjustable acceleration and speed parameters Electronic Ballast Supplied as standard with every fixture...

Page 6: ...6 Giotto spot rel 1 00 Accessories Light Dome for outdoor protection cod 0202406 Single flight case cod 0061741 Double flight case cod 0061744 Optional clamp unit cod 0202403...

Page 7: ...TTING VIA BUILT IN MICROCOMPUTER CONTROL SIGNAL USITT DMX 512 OR RS 232 DMX CONTROL CHANNELS 18 CH AUTOMATIC REPOSITIONING VIA OPTICAL SENSORS CONSTANTLY CONTROLLING PAN AND TILT POSITION AND CORRECTI...

Page 8: ...propriate flightcase or the original packing which have an suitable shock proof support system Remember to ALWAYS unlock the mechanism BEFORE switching on the fixture The fixture is locked and unlocke...

Page 9: ...ing the lamp bulb with your fingers Should this happen clean it before use with a soft cloth and alcohol then clean with a dry cloth 5 fig 3 Tighten the screws again making certain that the lamp wires...

Page 10: ...t with the following characteristics 1 7 Installing the fixture on a support structure Read the following safety information before proceeding with the installation of the fixture Fixture not for dome...

Page 11: ...re s base Don t fix the safety chain to the handles Remember to unlock the PAN and TILT locking system once the fixture is mounted on the support structure safety chain socket 15 OK OK OK in out dmx c...

Page 12: ...h certain cable lengths this could cause them to cancel the original signals The termination is prepared by soldering a 120Ohm 1 4 W resistor between pins 2 and 3 of the 5 pin male XLR connector see d...

Page 13: ...Appendix 2 2 RS232 connection For this connection use good quality screened coax cable RG58 50Ohms to avoid problems with signal transmission and faulty fixture operation Connectors must always be 5 p...

Page 14: ...rs 3 1 Navigating in the menu When it s switched on the fixture runs a start up reset procedure and the display indicates if there s an input signal or not The 3 keys under the display are for selecti...

Page 15: ...cords total fixture operating time SIGN DMX Signal DMX selected RS 232 Signal RS 232 selected SMD 16 bit 8 bit Allows to select movement resolution Default configuration 16 bit EN Remote control of la...

Page 16: ...y it s possible to allocate the same start channel to several fixtures in this case the fixtures will all follow the same commands but can t be controlled separately To address fixtures correctly proc...

Page 17: ...ge on the display will start to flash 4 Use the UP DOWN keys to select the new starting or ending angle 5 Press ENTER to confirm 3 4 Direction of Tilt movement This function allows to decide the direc...

Page 18: ...e real elapsed time for the lamp about to be fitted To reset the elapsed time meter proceed as follows 1 Connect Giotto Spot to the power supply wait till it has completed reset operations and DMX sig...

Page 19: ...ery low speeds In 8 bit mode the number of steps is 256 which nevertheless allow precise movements 1 Connect Giotto Spot to the power supply wait till it has completed reset operations and DMX signal...

Page 20: ...pot to the power supply wait till it has completed reset operations and DMX signal appears on the display 2 Use the UP DOWN keys to find the Test menu 3 Press ENTER and hold it down for a few seconds...

Page 21: ...Connect Giotto Spot to the power supply wait till it has completed reset operations and DMX signal appears on the display 2 Use the UP DOWN keys to find the SLLF menu 3 Press Enter to confirm The mess...

Page 22: ...Ch8 Shutter Strobe Shutter and strobe with music sync Black out gobo and colour change See table Ch9 Dimmer The dimmer is partially electronic and partially mechanical Linear range 0 255 Ch10 Rotation...

Page 23: ...obtained which blacks out projection for a moment when colours are changed DMX VALUE CENTRAL VALUE FUNCTION 0 7 3 WHITE 8 14 11 PINK 15 21 18 MAGENTA 22 28 25 LAVENDER 29 35 32 BLU LIGHT 36 42 39 AZUR...

Page 24: ...both clockwise and counterclockwise and the position can be stored if required DMX VALUE CENTRAL VALUE FUNCTION 0 8 4 WHITE A WHITE B 9 17 13 WHITE A WHITE 1B 18 26 22 WHITE A GOBO 2B 27 35 31 WHITE A...

Page 25: ...DMX512 Level range 0 255 FUNCTION 0 CLOSED 000 255 LINEAR REGULATION 255 OPEN DMX VALUE CENTRAL VALUE FUNCTION 0 7 4 8 15 12 16 23 20 24 31 28 32 39 36 40 47 44 48 55 52 56 63 60 64 71 68 72 79 76 80...

Page 26: ...iply projected images by 4 or 9 obtaining eye catching graphic decorative effects The prisms cannot be superimposed so must be selected singly Lastly the prism system is completely independent from th...

Page 27: ...ers and the color conversion filters D46CTO and D461 2CTO It s possible to superimpose these filters with the 24 possible colors available thus obtaining two tone projections in various shades DMX VAL...

Page 28: ...er In this case the lamp will ignite automatically without waiting to receive the command from the lighting console In the event of the lamp being switched off accidentally it s advisable to wait at l...

Page 29: ...46 14 237 20 216 65 150 110 93 155 45 14 238 21 214 66 149 111 92 156 45 13 239 22 213 67 147 112 91 157 44 13 240 23 211 68 146 113 90 158 43 12 241 24 209 69 145 114 88 159 42 12 242 25 208 70 143...

Page 30: ...M 001235 SGM Elettronica srl Via Pio La Torre 1 61010 Tavullia PS Italy Tel 39 0721 476477 Fax 39 0721 476170 e mail info sgm it http www sgm it...

Reviews: