GENERAL
SANIMARIN
®
is a WC equipped with a pump/macerator
which installed and used correctly will give reliable and
consistent service for many years. SANIMARIN
®
is for marine
or mobil unit use. Please follow these installation
instructions, paying attention to the following warnings;
"
" Possible danger to personnel,
"
" Warning of possible electrical hazard,
"
WARNING
" Possible danger of damage to the macerator.
APPLICATION
SANIMARIN
®
uses an electronic programmer which
operates as follows;
• STANDARD Operation: press the NORMAL pad on the
control console. Cycle time 19 secs.
Water consumption: 2.2 lit.
• ECO Cycle: press the ECO pad on the control console.
Cycle time 10 secs.
Water consumption: 1.2 lit.
• DRAINING Cycle:
press the EMPTY pad on the control
console.
1
DIMENSIONS
(see drawing n° 3 page 2)
3
TECHNICAL DATA
Applications
discharge of a WC
Max. vertical evacuation
3 m
Max. horizontal evacuation
30 m
Nominal power
320 W in 12 V version
400 W in 24 V version
Electrical class
III
Isolation level
IPX4
Net weight
SANIMARIN
®
31
17,5 Kg
SANIMARIN
®
35
21 Kg
SANIMARIN
®
48
24,5 Kg
SANIMARIN
®
Elite
26.5 Kg
SANIMARIN
®
Bidet 35
21 Kg
CAUTION :
This product should not be used for any other
purpose other than that described here. The minimum
discharge pipe inner diameter should be 19mm.
4
PERFORMANCE CURVE
(see drawing n° 5 page 2)
5
INSTALLATION GUIDE
FIXING BOWL TO THE FLOOR
a
– Draw the outline of the base on the floor, in the area
around the fixing holes in the ceramic bowl.
b
– Measure 15 mm from the outline drawn, position the
brackets and drill through the middle of the holes.
c
– Screw the brackets in place, leaving them loose, they
will be tightened once the bowl has been fitted.
d
– Fit the bowl.
A
6a
6
Note: wait until all the connections have been made
before fixing the bowl definitively in place.
Note:
on the SANIMARIN
®
35
, there is only one bracket, in
the front. The two screws at the back are placed vertically.
CONNECTING THE WASTE PIPE AND THE WATER
SUPPLY PIPE
Connect the 38/38 mm diameter bend to the check valve
and the waste pipe, and then fix in place with clip .
Water supply pipe.
To be connected to a seawater
pump (supplied as an option), or to the pressurized onboard
freshwater system. The pressure in the system must be at
least 1.7 bar.
Note:
it is possible to fit a seawater pump other than the
pump supplied as an option, provided that the current
requirement is not more than 16 A, if the pump is to be
controlled via the touchpad. There is another possible
assembly principle: that of a water supply system, in which
the pump cuts in when the pressure drops.
FITTING THE CONTROL TOUCHPAD
The touchpad
and must be fitted in a position where
it does not interfere with use of the seat and cover, and it
must not be placed more than 1.50 m (length of the
electrical wiring) from the electrical control box. Drill out
a 57 mm diameter hole and fix the holder with the four
screws, making sure that the clips are correctly placed at
the top and the bottom. Insert the electrical wiring in the
hole. Clip the touchpad in place.
FITTING THE CONTROL CONSOLE FOR THE BLACK
WATER TANK (OPTION)
Assembly similar to that of the touchpad. Connect the electrical
wiring to the connector on the touchpad wiring.
ELECTRICAL CONNECTIONS
a
- Fix the box in a dry, protected location.
b
- Connect the wiring from the touchpad to the box.
c
– Fit the connector protection cover .
d
– Drill out a 28 mm diameter hole for the motor wiring and
the solenoid valve for the toilet
e
– Insert and connect the electrical wiring from the
SANIMARIN
®
to the electrical box, using the sealed
connector. Lastly, connect the electrical box to the
battery, making sure that the cross-section of the wires is
sufficient (2.5 sq. mm up to 3 m and larger if a greater
length is required).
The electricity supply to the SANIMARIN
®
must be
connected directly to the boat’s electrical switchboard, and it
must be used solely for that equipment. It is advisable to add
a 25 A fuse in a 12 Volt system, and a 15 A fuse in a 24 Volt
system. Our equipment is fitted with its own safety device, a
circuit breaker located in the electrical control box. If the
circuit breaker opens, you can reset it without having to open
the electrical box (see diagram 6h - part ).
Make sure the wires are connected correctly:
Red wire = positive (+) terminal,
black wire = negative (-) terminal
1
J
R
6e
1
6d
W
C
L
6c
1
D
U
Q
6b
UK
LIST OF ACCESSORIES INCLUDED
(see drawing n° 2)
Tools required to fit a SANIMARIN
®
• A drill with a set of 4 mm to 8 mm drill bits
• A hole saw 57 mm in diameter
• A hole saw 28 mm in diameter
• A reversible screw gun
• Flat blade and cross-tip screwdrivers
• A 10 mm box spanner
2