Sanicubic 2 Troubleshooting Guide 

Alarm Instructions – troubleshooting guide

Anomaly Detected

Causes/Problems

Solutions

Flashing red alarm LED

Water Level Detection

Clear activation tubes

Replace pressure switch if 

faulty

Call Saniflo technical

Steady red alarm LED

Blocked vent line

AAV Installed

Blocked pump line

Motor jammed or failed

Discharge line beyond specs

Faulty control board

Clear vent line

Remove AAV and replace with 

carbon block filter or vent to 

atmosphere

Check cutter assemblies for 

blockages & impellers for 

residual matter

Check discharge line against 

manufacturer’s installation 

guides

Contact Saniflo Technical

Flashing yellow (power) alarm 

LED 

Mains failure

Power disruption

Check the 

powerpoint/fuse/circuit 

breaker.

Press both motor override 

buttons for 4 seconds. This 

will reset fault indication and 

stabilise the power light.

Contact Saniflo Technical

Summary of Contents for Saniflo Sanicubic 2

Page 1: ......

Page 2: ...Troubleshooting Quick Guide Sanicubic2 Lifting Station ...

Page 3: ...ckages from grease fats toilet paper etc good practice is to have a dishwasher connected to pump if grease might be an issue Sanicubic 2 lifting stations can be affected by poor installation or other usage issues This troubleshooting guide is also available as a PDF download on the Plumber Portal where you accessed this guide If you don t find your issue covered here please call our technical hotl...

Page 4: ...fter approx 45 60 mins Look for origin of overheating possible blockages in pump line Blocked pressure tubes due to fat grease toilet paper etc or faulty pressure switch Red fault indicator will flash on control panel and on remote alarm panel Remove clear pressure tubes Check replace pressure switch if needed Call Saniflo technical for further assistance Symptom The motor does not activate No noi...

Page 5: ...k correct mounting of pump cover and impeller Test and replace capacitor Motor windings failure Electrician to test windings and replace motor if required Symptom The motor hums but does not run activate Sanicubic 2 Troubleshooting Guide Given that Sanicubic 2 has two motors we need to clarify that one or both motors are still working This can be done by pressing the motor override buttons for eac...

Page 6: ...eller The length or height of the pump line installation is over the specification or too many bends elbows Check installation against manufacturer s installation guides The integral non return valve NRV is blocked faulty damaged Check clean replace integral NRV Defective control board Consult Saniflo technical department Symptom The motor runs continuously Sanicubic 2 Troubleshooting Guide ...

Page 7: ...f needed repair the fixtures connected to the pump The integral non return valve NRV is blocked faulty damaged Check clean replace integral NRV Defective control board Consult Saniflo technical department Symptom The motor activates intermittently Sanicubic 2 Troubleshooting Guide ...

Page 8: ...e is faulty or discharge line blocked Check impeller pump cover plate Discharge line Partially blocked drainage prior to pump Check drain lines and clear blockages The length or height of the pump line installation is over the specification or too many bends elbows Check installation against manufacturer s installation guides Symptom Bad or very slow evacuation Sanicubic 2 Troubleshooting Guide ...

Page 9: ... close to activation level of pump Outlet of lowest fixture must be minimum 275mm above base of pump Raise fixture appliance or lower pump Bad smell Pump not vented to atmosphere Vent to atmosphere or install 2 way carbon block filter Plastec Ecovent or Studor Maxi Filtra Sanicubic 2 Troubleshooting Guide ...

Page 10: ...d Discharge line beyond specs Faulty control board Clear vent line Remove AAV and replace with carbon block filter or vent to atmosphere Check cutter assemblies for blockages impellers for residual matter Check discharge line against manufacturer s installation guides Contact Saniflo Technical Flashing yellow power alarm LED Mains failure Power disruption Check the powerpoint fuse circuit breaker ...

Page 11: ... and kitchens anywhere and without major work Our products are manufactured in France and comply with the strictest requirements and consistently exceed customer expectations To maintain our high level of excellence our R D and engineers are constantly developing state of the art products to suit any projects from light domestic to heavy commercial applications ...