Possible Reasons
Remedies
Electrical supply is turned off or faulty
(If power disruption has been detected, power
indicator light on control panel should be flashing)
Check the powerpoint/fuse/circuit breaker.
Press both motor override buttons for 4 seconds. This
will reset fault indication and stabilise the power
light.
The motor has gone into thermal shutdown – feel top
of motor trap for warmth as an indictor
Motor will try & restart after approx 45/60 mins.
Look for origin of overheating – possible blockages in
pump line
Blocked pressure tubes due to fat, grease, toilet
paper etc or faulty pressure switch (Red fault
indicator will flash on control panel and on remote
alarm panel)
Remove & clear pressure tubes
Check & replace pressure switch if needed
Call Saniflo technical for further assistance
Symptom
The motor does not activate – No noise
Given that Sanicubic 2 has two motors, we need to clarify that one or both motors are still working. This can
be done by pressing the motor override buttons for each motor on the main control panel.
Sanicubic 2 Troubleshooting Guide