36
◆ Weighing Mode 7 – Accumulating Mode 1 (F21 – 07 Setting)
Relay Output
※
The weight will be measured with absolute value, it doesn’t /-.
Relay
Output
Relay
Outut
OUT 1
Current weight ≥ SP1(ON)
Current weight < SP1(OFF)
OUT 2
Current weight ≥ SP2(ON)
Current weight < SP2(OFF)
OUT 3
Current weight ≥ SP3(ON)
Current weight < SP3(OFF)
OUT 4
At SP3
after “t1” during “t2” ON
WEIGHT