27
Serial Communication Speed selection(Extended Serial port)
F61
0
2,400bps
5
28,800bps
1
4,800bps
6
38,400bps
●
2
9,600bps
7
57,600bps
3
14,400bps
8
76,800bps
4
19,200bps
9
115,200bps
DATA Transference Method selection(Extended Serial port)
F62
●
0
Simplex Mode / Stream Mode
1
Duplex Mode / Command Mode
2
Print Mode
“Check-Sum” detection selection (Under F62-01 setting, only)
F64
●
0
Check-Sum Not Use
1
Check-Sum Use
Under Stream Mode select the way transmit data protocol/frame (extended port)
F65
●
0
Transmit by Protocol
1
Transmit by frame (in case of using specific utility)
Caution : In case of “Transmit by frame” & under 14400bps setting(F61), the speed of
system will be slow.
DATA Transference Mode selection (Extended Serial port)
F66
●
0
Weighing Data will be transferred continuously
1
Single time data transference, Whenever the weight is steady over than
Empty range.
2
Single time data transference, first weight steady point over than Empty
range.
3
Data transference, Whenever “Print” key input
DATA Transference Format selection (Extended Serial port)
F67
●
0
Format 1 (recommended when use external display)
1
Format 2. (Format 1 + ID No.)
2
Format 3.
3
CAS Format
Print Mode selection (Extended Serial port)
F68
●
0
Manual Print : Whenever “Print” key input.
1
Auto print (When the first Steady point over “EMPTY” range
or Whenever “Print” key input.)
2
Auto print (Whenever Steady status at over the range of “EMPTY”
or Whenever “Print” key input.)