- 40 -
6-1-5. Command Mode
Under “Command Mode”, Indicator will recognize the receipt of Order based on 02h(STX)
and 03h(ETX) signal, and transfers 06h(ACK), 15h(NAK).
Error Code (Function 304 - 01 or 311 - 01)
0 (30h)
Normality
3 (33h)
Number data Error
1 (31h)
Check-Sum Error
4 (34h)
Excess of write data’s allowable
range
2 (32h)
Data length Error
6-1-6. Read Command
Subject
Command
Length of transmission data
Current Weight
STX ID RCWT ETX
22 byte
Current data
STX ID RCWD ETX
46 byte
Current date data
STX ID RDAT ETX
14 byte
Current time data
STX ID RTIM ETX
14 byte
Tare weight
STX ID RTAR ETX
18 byte
6-1-7. Write Command
Subject
Command
Length of transmission
data
Zero
STX ID WZER ETX
8 byte
Tare
STX ID WTAR ETX
8 byte
Tare Reset
STX ID WTRS ETX
8 byte
Hold
STX ID WHOL ETX
8 byte
Hold Reset
STX ID WHRS ETX
8 byte
STX ID WPRT ETX
8 byte
Grand total Print
STX ID WGPR ETX
8 byte
Delete Grand total
STX ID WGTC ETX
8 byte
Date setting
STX ID WDAT DATE
(YYMMDD) ETX
14 byte
Time setting
STX ID WTIM TIME
(HHMMSS) ETX
14 byte