│ 3 Using the generator
Fig. 3: Direct galvanic connection via conductor loop
A
WARNING! Risk of injury from electric shock
High voltages can be applied to exposed parts of the lines.
●
Disconnect electrical lines before locating.
● Observe the specified sequence of actions.
The generator is switched off.
1. Attach one terminal of the cable set to an exposed part of the
line to be energized.
2. Attach the second terminal of the cable set to another ex-
posed part of the line to be energized.
3. Connect the cable set to the generator.
4. Switch on the generator.
5. Set the frequency (section 3.2.4).
6. Set the output power (section 3.2.5).
The line is energized with the selected settings.
3.2.3
Connection with earthing spike
The direct galvanic connection with earthing spike can be used
if there is only one connection option on the line.
The earthing spike is placed outside of buildings in the ground.
The distance from the earthing spike to the line must be at least
3 metres. The electrical conductivity of the ground is improved
by moisture. SEWERIN recommends: Moisten the ground if nec-
essary.