3 Using the generator
│
5
3
Using the generator
3.1
Switching the generator on and
off
Switching on
●
Press the ON/OFF key for approx. 1 second.
A start screen with the
firmware version will appear briefly on
the display. The main view then appears.
Switching off
●
Press the ON/OFF key for approx. 2 seconds.
The generator switches off.
3.2
Energize line
3.2.1
General information for locating by energizing
In order to be able to locate a line, it must carry a current with a
certain frequency, so that an electromagnetic field is generated.
This field is then located.
Lines that are not carrying a current must be energized for lo-
cating.
Direct energizing involves supplying power from a generator to
the line via a cable. This is only possible if a galvanic connection
can be made to at least an exposed part of the line.
The following options are available for direct galvanic connection:
●
Connection via conductor loop
●
Connection with earthing spike
3.2.2
Connection via conductor loop
Two connection options on the line are required for direct galvan-
ic connection via a conductor loop. The line to be located must