background image

 

5 Appendix

 │ 

15

Appendix

5.1 

Technical data

Device data

Dimensions (W x D x H)

115 x 114 x 60

 

mm

Weight

410 g

Material

polycarbonate (housing)

Certificate

Certificate

FCC, CE

Features

Display

2" FSTN display (240 x 128 pixels, LED 

backlight)

Processor

DSP 16

 

bit

Operation

membrane keypad

Operating conditions

Operating temperature

-20 – 50 °C

Transmitting power

-20 – 50 °C

Humidity

15% – 90% non-condensing

Protection rating

IP 65

Non-permitted operating 

environments

in potentially explosive areas

Power supply

Power supply

lithium ion battery (rechargeable) 

[1357-0002], built-in

Operating time, minimum

6 h

Operating time, maximum

40 h

Battery power

24 Wh

Charging time

< 6 h

Charging temperature

0 – 40 °C

Charging voltage

12 V

Charging current

0.6 A

Charger

M4 AC/DC adapter

Summary of Contents for FERROPHON FG 50

Page 1: ...02 09 2019 a 107631 en FERROPHON FG 50 generator Operating Instructions...

Page 2: ...FG 50 generator Arrow keys Up key Down key ON OFF key Frequency keys Fig 1 FG 50 generator viewed from various angles Cable set connection Charging socket Display...

Page 3: ...FG 50 generator kHz mA Frequency Output power Current Fig 2 Display with main view Charge...

Page 4: ...Illustration of warnings in this document A WARNING Risk of personal injury Could result in serious injury or death NOTICE Risk of damage to property...

Page 5: ...ection via conductor loop 5 3 2 3 Connection with earthing spike 6 3 2 4 Set frequency 8 3 2 5 Setting the output power 8 3 2 6 Stop energizing 9 4 Maintenance 10 4 1 Charging the batteries 10 4 1 1 C...

Page 6: ...owledge The original German version is authoritative Right of reproduction No part of this document may be edited duplicated or circulated in any form without the express consent of Hermann Sewerin Gm...

Page 7: ...ons and property For this reason observe the following safety information without fail Observe all the applicable safety standards and accident pre vention regulations Use the product only as intended...

Page 8: ...connected M4 AC DC adapter M4 vehicle cable Connection cable in case SK 10 Cable set connection For connecting the universal cable set 2 3 Power supply The generator can be operated with rechargeable...

Page 9: ...hium ion rechargeable battery A WARNING Risk of explosion due to short circuit Faulty lithium ion rechargeable batteries can explode due to internal short circuit Components containing faulty lithium...

Page 10: ...requency so that an electromagnetic field is generated This field is then located Lines that are not carrying a current must be energized for lo cating Direct energizing involves supplying power from...

Page 11: ...ex posed part of the line to be energized 3 Connect the cable set to the generator 4 Switch on the generator 5 Set the frequency section 3 2 4 6 Set the output power section 3 2 5 The line is energiz...

Page 12: ...ator before moving the earthing spike The generator is switched off 1 Attach one terminal of the cable set to an exposed part of the line to be energized 2 Insert the earthing spike firmly into the gr...

Page 13: ...tput power of the FG 50 generator can be adjusted to the conditions As soon as the generator is switched on it will supply an output power of up to 1 Watt in battery operation Whether the generator ca...

Page 14: ...the Up key to increase the output power Press the Down key to reduce the output power 3 2 6 Stop energizing Once the locating process has been completed the following steps must be carried out in the...

Page 15: ...within the per mitted range There are two ways to charge the FG 50 generator simultaneously with the AQUAPHON system components in the SK 10 case individually by AC DC adapter or vehicle cable 4 1 1 C...

Page 16: ...using the L AC DC adapter or the L vehicle cable Charging starts automatically The charging process is complete after less than 6 hours 4 1 2 Charging batteries individually using the AC DC adapter o...

Page 17: ...maged me chanically or by electrostatic discharge The lithium on battery may only be removed if you have legit imate grounds to suspect that the battery may be defective Only SEWERIN Service personnel...

Page 18: ...y using an ESD workstation Switch off the generator 1 Undo the four screws on the bottom section of the housing 2 Carefully lift off the bottom section of the housing 3 Disconnect the electrical suppl...

Page 19: ...ional Only regular maintenance can ensure that the generator is al ways ready for use 4 5 Dealing with problems Problem Possible cause Corrective action FG 50 cannot be switched on Insufficient power...

Page 20: ...eypad Operating conditions Operating temperature 20 50 C Transmitting power 20 50 C Humidity 15 90 non condensing Protection rating IP 65 Non permitted operating environments in potentially explosive...

Page 21: ...al batteries packed with equipment net weight of battery batteries 0 096 kg 5 2 Accessories Part Order number L12 V AC DC adapter LD26 10000 L12 V vehicle cable ZL05 10200 SK 10 case ZD63 10000 Other...

Page 22: ...atalogue EWC governs the disposal of appliances and accessories in accordance with EU Directive 2014 955 EU Waste EWC code Device 16 02 13 Disposable battery rechargea ble battery 16 06 05 Alternative...

Page 23: ...ith earthing spike 6 F Firmware version 1 5 Frequency keys 8 G Generator operating principle 3 power supply 3 switching off 5 switching on 5 L Lithium ion rechargeable battery charging 10 identifying...

Page 24: ...ower Avenida Sur del Aeropuerto de Barajas 28 Of 2 1 y 2 2 28042 Madrid Espa a Tel 34 91 74807 57 Fax 34 91 74807 58 www sewerin es info sewerin es Sewerin Portugal Lda Rua do Senhor dos Milagres 16 2...

Reviews: