6
Operation and service
Status displays
Operating Instructions Basic Unit – MOVITRAC
®
B
27
6.3
Status displays
6.3.1
LED flash codes
The LED on the front of the unit signals the following states:
6.4
SEW Electronics service
6.4.1
Hotline
Call the Drive Service Hotline to talk to an SEW-EURODRIVE service specialist on
365 days a year, 24 hours a day.
Simply dial the prefix
01805
and then enter the key combination
SEWHELP
. Or simply
dial
018057394357
.
Status
Display
(optional with FBG)
Color
Flash code
"ENABLE"
Speed
Green
Constant light
"ENABLE" at current limit
Speed
Green
Rapid flashing
"CURRENT AT
STANDSTILL"
dc
Green
Slow flashing
"NO ENABLE"
Stop
Yellow
Constant light
"FACTORY SETTING"
SEt
Yellow
Rapid flashing
"CONTROL.INHIBIT"
oFF
Yellow
Rapid flashing
"24 V operation"
24U
Yellow
Slow flashing
FBG manual operation
active or inverter stopped
using "stop" button
FBG manual operation
symbol or "stop" is flashing
Yellow
On long, off briefly
Timeout
Errors 43 / 46 / 47
Green /
yellow
Flashing
Copy
Error 97
Red/yellow
Flashing
System error
Errors 10 / 17 ... 24 / 25 /
32 / 37 / 38 / 45 / 77 / 94
Red
Constant light
Overvoltage / phase failure
Errors 4 / 6 / 7
Red
Slow flashing
Overload
Errors 1 / 3 / 11 / 44 / 84
Red
Rapid flashing
Monitoring
Errors 8 / 26 / 34 / 81 / 82
Red
2 x flashing
TF motor protection
Errors 31 / 84
Red
3 x flashing