7.4.10 AC 400/500 V / 3-phase / size 3 / 15... 30 kW / 20... 40 HP
MOVITRAC
®
MC07B (3-phase supply system)
0150-503-4-00
0220-503-4-00
0300-503-4-00
Part number
828 528 4
828 529 2
828 530 6
INPUT
Permitted rated supply voltage
V
N
3 × AC 400 V
V
Mains
= AC 380 V – 10 % ... AC 500 V + 10 %
Rated supply frequency
f
N
50 / 60 Hz ± 5 %
Rated mains current 3-phase with
V
Mains
= AC 400 V
AC 28.8 A
AC 41.4 A
AC 54.0 A
OUTPUT
Output voltage
V
A
3 × 0 ... V
Mains
Recommended motor power under constant
load (with V
Mains
= AC 400 V)
P
Mot
15 kW
20 HP
22 kW
30 HP
30 kW
40 HP
Rated output current
with V
Mains
= AC 400 V
I
N
AC 32 A
AC 46 A
AC 60 A
Minimum permitted braking resistor value
(4-Q operation)
R
BW_min
15
Ê
12
Ê
GENERAL INFORMATION
Power loss at I
N
P
V
550 W
750 W
950 W
Current limitation
150 % I
N
for maximum 60 seconds
Connections
Terminals
6 mm
2
/ AWG10
10 mm
2
/ AWG8
16 mm
2
/ AWG6
Dimensions
W × H × D
200 × 465 × 251 mm / 7.9 × 18.3 × 9.9 in
Weight
m
15 kg / 33.1 lbs.