Level
Data
set
No
Code Function
Value range
(Factory setting
underlined)
Setting
after
commis-
sioning
1
2
3
1 2
X
X
48 IxR
I x R compensation
0...1
X
X
49 SC
Slip compensation
0...1
X
X
50 IN
Motor rated current
MC 0504: 0.00 ...2.85 A
MC 0504: 0.00 ...4.80 A
X
X
51 COS
Power factor x 100
0.00...100.00
X
X
52 NN
Motor rated speed
0...60,000 rpm
X
X
53 KIXR
K factor IxR compensation
0...1..255
X
X
54 KSC
K factor IxR slip
compensation
0.00...30.00
X
X
55 ISEL
Current controller selector
0...2
X
X
56 ILIM
Current limit
MC0504: 0.50.2.85...3.80 A
MC0508: 0.50.2.85...5.75 A
X
X
57 FILIM
Min. low. frequency
0.00... 15.00 ...999.00 Hz
X
X
58 RILIM
Deceleration ramp I
control
0.10... 50.00 ...999.00 Hz/s
X
X
59 TRIP
Ixt monitoring motor
MC0504: 0.50...1.90...2.00 A
MC0508: 0.90...3.20 A
Control functions
X
X
61 SOUTA Analog output X1:10
0...1...7 (
→
Sec. 3.4/4.3)
X
X
62 S1OUT Digital output 1 X1:8
0...1...10 (
→
Sec. 3.4)
X
X
63 S2OUT Digital output 2 X1:9
1...7...10 (
→
Sec. 3.4)
X
X
64 SINA
Potentiometer 1 (internal)
0...2
X
65 SINT
(Not for use)
Do not
change!
X
X
67 FST
Filter time constant
0...2...4
X
X
69 KOUTA SOUTA scaling
0...100...200%
Program
X
X
71 PROG Factory programming
0...9999 0 = inactive /
1 = active / 2 = special prog.
X
X
72 STRT
Start option
0...7 0=none /
1=autostart / 2=flying start /
3=1+2 / CCW inhibited /
5=1+4 / 6=2+4 / 7=1+2+4
X
X
74 PWM
PWM frequency
0...2 (7.8/15.6/3.9kHz)
Do not
change!
X
75 OPT1
(Not for use)
X
76 OPT2
X
77 OPT3
X
81 SIOC
X
82 SIOA
X
84 SIOT
X
X
86 KG
Scaling factor 10-G
0...1000
X
X
87 DISP
Actual value display
F, all values VAL
X
X
88 PSW1
Password 1 <PARA>
0...999
X
X
89 PSW2
Password 2 <CTRL>
0..573...999
X
94 MAXF
Absolute maximum
frequency
0...999 Hz
4
Commissioning
MOVITRAC
®
0500 - Operating Instructions
19