4.2.3
Manual operation / motorized potentiometer
-
Call up CTRL menu branch.
-
Enter password (factory setting 573) and confirm.
-
The frequency input for the inverter is 0Hz.
-
Set the required frequency input using the arrow
keys.
-
Start the inverter with [start/enter],
accelerate with ramp 32 RACC1.
-
Change the frequency input using the arrow keys.
-
To reverse input a negative frequency value. The
inverter will decelerate to 0Hz using ramp 33
RDEC1, reverse and accelerate to the frequency
input with ramp 32 RACC1.
-
The inverter will decelerate to standstill with ramp
33 RDEC1.
Fig. 7: Manual operation / motorized potentiometer
00409AXX
start
enter
stop
return
start
enter
start
enter
stop
return
stop
return
stop
return
stop
return
CTRL
PW
0
V
0
Hz
0.0
CTRL
start
enter
V
0
Hz
30.0
CTRL
V
30
Hz
30.0
CTRL
start
enter
V
0
Hz
--25.0
CTRL
V
25
Hz
--25.0
CTRL
V
50
Hz
50.0
CTRL
V
25
Hz
--25.0
CTRL
V
0
S T O P
CTRL
MENU
V
CTRL
4
Commissioning
MOVITRAC
®
0500 - Operating Instructions
15