Setting up the drive unit
4.4.1
Notes
•
Only mount the drive units to the plant structure together with a torque arm. Install-
ation without a torque arm is not permitted.
•
Clean the shaft ends thoroughly to ensure they are free of anti-corrosion agents
(use a commercially available solvent). Do not expose the bearings and sealing
rings to the solvent – damage to the material.
•
Carefully align the drive unit and the driven machine to avoid placing any unac-
ceptable strain on the shaft ends.
•
Do not butt or hammer the shaft end.
•
Ensure that cooling air supply is unobstructed and that air discharged by other
units does not influence cooling.
•
Use suitable cable glands for the supply leads (use reducing adapters if neces-
sary).
•
Seal the cable entry well.
•
Clean the sealing faces of the cover well before reassembling the unit.
•
Restore the corrosion protection if necessary.
•
Check the validity of the degree of protection using the information in the operating
instructions and the data on the nameplate.
Changing the mounting position
Observe the following information when you operate the drive unit in a mounting posi-
tion other than indicated in the order:
•
Mounting position M3 is only available in combination with the option “inte-
grated pressure compensation /PG". Observe the documentation "Integrated
Pressure Compensation (Option /PG)".
•
Adjust the position of the breather valve.
•
If present, adjust the position of the pressure compensation fitting.
4.4.2
Electronics cover
WARNING
Risk of burns due to hot surfaces.
Serious injuries.
•
Let the devices cool down before touching them.
NOTICE
Loss of the guaranteed degree of protection.
Possible damage to property.
•
When the cover is removed from the connection box, you have to protect the
cover and the wiring space from humidity, dust or foreign particles.
•
Make sure that the cover is mounted properly.
25887548/EN – 04/2019