6
Startup
Process data assignment – MOVIKIT® function module "5PD Velocity"
Operating Instructions – MOVIGEAR
®
performance
131
6.5
Process data assignment – MOVIKIT
®
function module "5PD Velocity"
Process
data
assignment
–
MOVIKIT®
function
module
"5PD
Velocity"
In the standard design, the device is delivered with the MOVIKIT
®
function module
"5PD Velocity".
In automatic mode, the device is controlled using the following process data configura-
tion:
PO
Function
PI
Function
PO1 Control word
PI1
Status word
PO2 Speed setpoint
PI2
Actual speed
PO3 Acceleration
PI3
Drive status/drive fault
PO4 Deceleration
PI4
Actual torque
PO5 Digital outputs
PI5
Digital inputs
For further information on the function and process data scaling of the MOVIKIT
®
func-
tion module "5PD Velocity", refer to the relevant documentation or the MOVISUITE
®
startup software.