9
Inspection and maintenance
Inspection and maintenance work
Operating Instructions – MOVIGEAR
®
performance
282
9.4.7
Replacing the gasket between connection box and electronics cover
Spare part kit
The gasket is available as a spare part (1, 10 or 50 pieces) from SEW‑EURODRIVE.
Steps
NOTICE
Loss of the guaranteed degree of protection.
Possible damage to property.
•
When the cover is removed from the connection box, you have to protect the
cover and the wiring space from humidity, dust or foreign particles.
•
Make sure that the cover is mounted properly.
1. Observe the notes in chapter "Preliminary work for inspection and maintenance".
2. Loosen the screws of the electronics cover and remove it.
5 min
X5
13
3_
1 X5
13
3_
2
X5
13
3_
3
X4
23
3_
1
X4
23
3_
2
25402432267