![SEW-Eurodrive MOVI-PLC basic DHP11B-T0 Manual Download Page 79](http://html.mh-extra.com/html/sew-eurodrive/movi-plc-basic-dhp11b-t0/movi-plc-basic-dhp11b-t0_manual_1250108079.webp)
8
Technical Data and Dimension Drawings
MOVI-PLC® basic DHP11B.. controller
Manual – MOVI-PLC
®
basic DHP11B.. controller
79
8.2
MOVI-PLC
®
basic
DHP11B.. controller
MOVI-PLC
®
basic
DHP11B.. controller
Unit design and part
number
•
MOVI-PLC
®
basic
DHP11B-T0: 1 820 472 4
•
MOVI-PLC
®
basic
DHP11B-T1: 1 820 822 3
•
MOVI-PLC
®
basic
DHP11B-T2: 1 820 823 1
Electrical supply
For all devices (MC07, MDX, MX, compact control) the following applies: You will have to supply the
binary inputs and outputs with DC24 V (X31:1/2) separately.
Installed in MOVIDRIVE
®
MDX61B:
•
Power consumption: P
max
= 4.5 W
•
The MOVI-PLC
®
basic
DHP11B.. controller is supplied with voltage by MOVIDRIVE
®
MDX61B via the
backplane connector.
•
In the case of disconnection from the power supply, continued function is guaranteed by DC 24
backup (external DC 24 V supply to X10:9/10 of MOVIDRIVE
®
MDX61B required).
Installed in MOVITRAC
®
B:
•
Power consumption: P
max
= 5.6 W
•
U = DC 24 V (–15 % / +20 %)
•
I
max
= 400 mA
•
The MOVI-PLC
®
basic
DHP11B.. controller can be supplied by MOVITRAC
®
B. To this end, connect
X26:3 (6) / 7 with X46:3 (6) /7 or with X12:9 / 8.
•
If MOVI-PLC
®
basic
DHP11B.. controller is supplied by DC 24 V by MOVITRAC
®
B, the function of
the controller is maintained after disconnection from the power supply. This requires an external
DC 24 V supply to X12:8 / 9 of MOVITRAC
®
B.
Installed in the MOVIAXIS
®
master module(MXM):
•
Power consumption: P
max
= 5.6 W
•
U = DC 24 V (–15 % / +20 %)
•
I
max
= 400 mA
•
The MOVI-PLC
®
basic
DHP11B.. controller can be supplied by the MOVIAXIS
®
switched mode
power supply module (MXS) or from an external voltage supply. For this purpose, connect X5
between the individual devices.
•
If the MOVI-PLC
®
basic
DHP11B.. controller is supplied by DC 24 V by the MOVIAXIS
®
switched
mode power supply module, the function of the MOVI-PLC
®
basic
DHP11B.. controller is maintained
after disconnection from the power supply (external DC 24 V supply to X16 of the MOVIAXIS
®
switched-mode power supply required).
Potential levels
The MOVI-PLC
®
basic DHP11B.. controller has the following potential levels:
•
Potential control / CAN 1 / RS485
•
Potential binary inputs and outputs
•
Potential system bus CAN 2
•
Potential PROFIBUS
Memory
•
Program memory: 512 kByte (for application program, incl. IEC libraries)
•
Data memory: 128 kByte (for IEC application)
•
Retain data: 16 kByte
•
System variables (retain): 8 kByte
Binary inputs
X31:3...X31:10
Internal resistance
Signal
level
Isolated (optocoupler), PLC-compatible (IEC 61131-2), sampling time 1 ms, unfiltered and filtered
(filter constant ca. 2 ms) available
Can be configured as binary input or output
X31:6...X31:10 are interrupt capable (response time < 100 µs)
R
i
À
3 k
Ê
, I
E
À
10 mA
DC (+13 V...+30 V) = "1" = Contact closed (according to IEC 61131)
DC (–3 V...+5 V) = "0" = Contact open (according to IEC 61131)
Binary outputs
X31:3...X31:10
Signal
level
PLC compatible, (IEC 61131-2) response time 1 ms
Can be configured as binary input or output
Maximum permitted output current I
A_max
= DC 150 mA per binary output
All 8 binary outputs can be subject to the maximum approved output current I
A_max
load at the same time.
"0" = 0 V
"1" = DC +24 V
P
i
f
kVA
Hz
n