4
Project Planning and Startup
For project planning using the MOVITOOLS® MotionStudio PC software
Manual – MOVI-PLC
®
basic DHP11B.. controller
35
Configure the parameters of the PC interfaces as follows:
• Click the right mouse button on the required "PC Communication Interface" and
select [Configure] in the [Options] menu.
• The following window opens. Set the parameters in accordance with the used inter-
faces.
Settings for a
system bus
interface
Set the baud rate [1] depending on the number of stations connected to the CAN bus.
– SEW default: 500 kBaud
– CANopen module: 125 kBaud
Settings for
COM interface
– Dropdown menu COM [1]: according to bus connection
If you use a USB-RS485 interface adapter, select the corresponding interface iden-
tified in parentheses by "USB".
– Dropdown menu baud rate [2]: 57600 kBaud
– Group
parameter
telegrams,
input window timeout [3]: 100
– Group parameter telegrams, input window retries [4]: 3
– Group multibyte telegrams, input window timeout [6]: 350
– Group multibyte telegrams, input window retries [5]: 3
58340AXX
[1]
58350AXX
[1]
[2]
[3]
[4]
[5]
[6]