PROFIBUS-DP-V1 Functions
Structure of the DP-V1 parameter channel
68
Manual – MOVI-PLC
®
basic DHP11B.. controller
MOVILINK
®
return codes of
parameter setting
for DP-V1
The following table shows the return codes that are returned by the SEW DP-V1 inter-
face in case of an error in the DP-V1 parameter access.
MOVILINK
®
Return Code (hex)
Description
0x0810
Illegal index, parameter index does not exist in the unit
0x0811
Function/parameter not implemented
0x0812
Read access only
0x0813
Parameter lock activated
0x0814
Factory setting is active
0x0815
Value for parameter too large
0x0816
Value for parameter too small
0x0817
Reserved
0x0818
Error in system software
0x0819
Reserved
0x081A
Parameter access only via RS485 interface
0x081B
Parameter is access-protected
0x081C
Reserved
0x081D
Invalid value for parameter
0x081E
Factory setting was activated
0x081F
Reserved
0x0820
Reserved
0x0821
Reserved
0x0822
Reserved
0x0823
Reserved
0x0824
Reserved
0x0505
Incorrect coding of management and reserved byte
0x0602
Reserved
0x0502
Reserved