34
Menu Servo
Channel type [Sound]
Typical use:
Raise the motor sound rpm
if
auxiliary drives are on or you actuate
hydraulic valves. (For models with hydraulic
or auxiliary drives. For Servonaut Sound-
modules choose [Normal] for the channel
you operate starter and horn with, not
[Sound].)
Function:
Idle speed or full throttle
forwards adjustable.
Possibility to set the
rpm for a sound module controlled by a
servo channel
Mixer function: All controls that affect this
channel are added up.
See chapter Mixer
Functions
Emergency off: Channel in neutral position
Test mode (yellow button): Yes
Channel type [Max]
Typical use:
Control light sets MFC-01
und MFC-02
Function: You can
adjust left and right full
deflection
and the
middle position for the
channel
.
Mixer function: Takes the maximum value
out of all controls that affect this channel.
See chapter Light Sets
Emergency off: Channel in neutral position
Test mode (yellow button): Yes
Channel type [Servo]
Typical
use:
Steering
;
all
channels
connected to servos (exception hydraulic
valve servo)
Function: You can
adjust left and right full
deflection
and the
middle position for a
servo
.
Emergency off: The connected servo moves
into neutral position (middle).
Mixer function: All controls that affect this
channel are added up.
Test mode (yellow button): Yes - see para-
graph test, page 32
Channel type [Valve]
Typical use:
Operate valve servos
Function: Allows
compensation of the
valve backlash
Valve [Backlash]
Hydraulic valves often need a certain
deflection to react. With backlash compen-
sation the hydraulic valves react directly
even with small control movements.
Mixer function: All controls that affect this
channel are added up.
Emergency off: Channel in neutral position
Test mode (yellow button): Yes
Channel type [Motor]
Typical use:
Electronic speed controller
(ESC) for the drive motor
; all drives that
run forwards and backwards, e.g. spindle
drives or a pump that moves forwards and
backwards. (Same as channel type [Servo]
but without a test mode, for security
reasons.)
Function: For an
ESC you can set
maximum speed forwards and back-
wards and the neutral position
.
Emergency off: Channel in neutral position
Mixer function: All controls that affect this
channel are added up.
Test mode (yellow button): No
Channel type [Pump 0–->]
For all
ESCs that move motors in only
one direction
e.g. flight controllers for
brushless motors. Full deflection on this
channel is 0% in one direction and +100%
in the other, center position +50%. Those
controller/motor combinations are often
used for hydraulic pumps.
Typical use:
ESC for hydraulic pumps
; all
drives that run in one direction only.
Function: For a
pump the idle is adjust-
able
as well. After the pump lag time (see
[Pump lag] page before) the channel acti-
vates the value set for [Off].
Emergency off: Channel activates the value
set for [Off]