Section 2
Installation Instructions
Part Number 020004000
10/13
2-9
Electrical
GENERAL
MINIMUM CIRCUIT AMPACITY
The minimum circuit ampacity is used to help select the
wire size of the electrical supply. (Minimum circuit
ampacity is not the beverage/ice machine’s running amp
load.) The wire size (or gauge) is also dependent upon
location, materials used, length of run, etc., so it must be
determined by a qualified electrician.
ELECTRICAL REQUIREMENTS
Refer to Machine Model/Serial Plate for voltage/
amperage specifications.
VOLTAGE
The standard voltage for CEV Series dispensers is
120VAC-60Hz 1 Ph. A power cord is provided with
120VAC-60Hz models only. 220/240 Volts - 50 Hz - 1 Ph,
208/230 Volts - 60 Hz - 1 Ph are also available.
MINIMUM CIRCUIT AMPERAGE CHART
REFRIGERANT
Optimum Ambient Conditions are between 50°F and
95°F (10°C and 35°C).
Grounding Instructions
This appliance must be grounded. In the event of
malfunction or breakdown, grounding provides a path of
least resistance for electric current to reduce the risk of
electric shock. This appliance is equipped with a cord
having an equipment-grounding conductor and a
grounding plug. The plug must be plugged into an
appropriate outlet that is properly installed and grounded
in accordance with all local codes and ordinances.
!
Warning
All wiring must conform to local, state and national codes.
Dispenser
Voltage/Cycle
Fuse Size
Circuit
Amps
CEV-30,
CEV-40
120/60
20 amp
8.2 Operating
amps
13 FLA
220/50, 240/50,
208/60, 230/60
10 amp
4.5 Operating
amps
7.0 FLA
Dispenser
Voltage/Cycle
Refrigerant
Compressor
CEV-30,
CEV-40
120/60, 220/50,
240/50, 208/60,
230/60
R-134a - 8 oz
1/3 HP
Important
Due to continuous improvements, this information is
for reference only. Please refer to the dispenser
serial number tag to verify electrical data. Serial tag
information overrides information listed on this page.
!
Warning
Risk of electrical shock. Connect to a properly
grounded outlet only.
!
Warning
Improper connection of the equipment-grounding
conductor can result in a risk of electric shock. The
conductor with insulation having an outer surface
that is green with or without yellow stripes is the
equipment grounding conductor. If repair or
replacement of the cord or plug is necessary, do not
connect the equipment-grounding conductor to a
live terminal. Check with a qualified electrician or
serviceman if the grounding instructions are not
completely understood, or if in doubt as to whether
the appliance is properly grounded. Do not modify
the plug provided with the appliance — if it will not fit
the outlet, have a proper outlet installed by a
qualified electrician.