Installation Instructions
Section 2
2-4
Part Number 020004000
10/13
Selecting Locations
The CEV may be island-mounted or installed on a front
or rear counter. Locate the CEV so the following
requirements are satisfied: CEV is for indoor use only
and must NOT be placed in an area where a water jet or
similar high pressure sprayer could be used.
1. CEV must be installed near a properly grounded
electrical outlet with proper electrical requirements
fused at proper amperage or circuit connected
through an equivalent HACR circuit breaker with
ELCB (GFCI). REFER TO UNIT NAMEPLATE FOR
THE REQUIRED POWER CIRCUIT OPERATING
VOLTAGE. HERTZ AND THE MINIMUM CIRCUIT
AMPACITY OF THE CEV. No other electrical
equipment should be connected to this circuit. ALL
ELECTRICAL WIRING MUST CONFORM TO
NATIONAL AND LOCAL ELECTRICAL CODES.
MAIN PLUG MUST BE ACCESSIBLE FOR
DISCONNECTION.
2. A minimum of 15-inches clearance must be
maintained above the CEV to the nearest
obstruction (shelf, cupboard, ceiling, etc.) and 4-
inches clearance between the back of the CEV and
the wall and 12-inches between each side and the
wall. CEV has a top air outlet and is to remain free of
all objects. Do not place anything on top of the CEV.
The rear grill of the CEV must be unobstructed to
allow air to enter the hood. This will also allow
access to the condenser filter for cleaning.
3. If a permanent drain is to be used place CEV close
to a permanent drain in order to route the drain pan
hose to the permanent drain. Water tank overflow
hose goes into the drain pan.
PLACING UNIT IN THE OPERATING POSITION
The CEV must be level horizontally from right to left and
front to rear. CEV inlet supply lines, power cord, and
drain pan hose must either be routed out of the CEV
base rear access hole, or through a hole cut in the
countertop under the CEV Unit. Proceed to applicable
installation procedure. Two plastic tubing brackets are
mounted under the CEV to hold the lines in place. The
rear access cover may be removed, turned and installed
to provide a brace to prevent the CEV from being
pushed flat against the wall.Dimensions
Island Mount
Place the CEV in location on the countertop flush with
the countertop edge. Mark CEV’s center line on the edge
of the countertop, then move the CEV to one side.
Starting at the center line mark on the edge of the
countertop, measure back 12-inches for the location of a
hole at least 4-inches to be cut into the countertop. Cut
at least a 4 inch hole in the countertop where indicated.
Place the CEV in position over the hole. Route the inlet
supply lines, power cord, carbonator tank purge tube
and drain pan hose down through the hole in the
countertop.Install the line outlet plug, provided with the
CEV in the base back access hole. The area around the
inlet supply lines at the flanged hole behind the front
access panel must be closed and sealed.
Counter Mount
Place the CEV in location on the countertop. Route CEV
inlet supply lines, power cord, carbonator tank purge
tube and drain pan hose out of the base back access
hole. Area around inlet supply lines at flanged hole
behind front access panel must be closed and sealed.