CHAPTER 2. ASTERX SB SX OVERV
I
EW
Time to first fix
Cold Start
2
<45s
Warm Start
3
<20s
Re-acquisition
avg. 1s
2
No information available (no almanac, no approximate position)
3
Ephemeris and approximate position known
2.1.2 Physical and Environmental
Size:
102 x 36 x 111 mm (4.0 x 1.4 x 4.4 in)
Weight:
460 g (1.01 lb)
I
nput voltage:
5 to 36 V DC
Power consumption:
1.5 W typical
Operating temperature:
-30
◦
C to +65
◦
C
(-22
◦
F to +149
◦
F)
Storage temperature:
-40
◦
C to +75
◦
C
(-40
◦
F to +167
◦
F)
I
ngress Protection:
I
P68
Humidity
M
I
L-STD810G, Method 507.5, Procedure
I
Dust
M
I
L-STD-810G, Method 510.5, Procedure
I
Shock
M
I
L-STD-810G, Method 516.6, Procedure
I
/
II
Vibration
M
I
L-STD-810G, Method 514.6, Procedure
I
8
Summary of Contents for AsteRx SB Sx