Installation
1–10
700-0099 R008
1.6.5. Wake On Alarm Installation (Optional)
When the Wake on Alarm function is enabled, if alarm 1 is triggered, the system
powers up and starts recording. The system takes about one minute to power up and
start recording, depending on environment conditions. This circuit activates with the
application of 12 volts to the red wire in the two pin Alarm 1 socket on the back of the
DVR.
To wire the Wake on Alarm feature:
1. Connect the DVR’s back panel alarm input harness connection (2 pin) so that pin
1 (red wire) is toggled to a 12-to-24 VDC source to trigger power.
2. Connect or remove the black wire of the alarm input harness.
3. Configure the DVR Alarm settings as described in the Alarm Menu, on page 4-7.
To wire the Wake on Alarm feature with a Diagnostic Button:
1. On the Diagnostic Button cable, cut the green wire just before it enters the socket.
2. Extend and connect the green wire to an input wire on the Signals harness.
3. Configure the DVR Alarm settings as described in the Alarm Menu, on page 4-7.
CAUTION
The Wake on Alarm starts the DVR when an alarm is triggered. The DVR
takes about 1 minute to boot up before it can begin recording. It cannot
instantly capture the alarm event.
Important:
If you are using the Diagnostic Button and cable, and require the Wake on
Alarm feature, the Diagnostic Button cable must be rewired as shown in Figure 1-6.
Figure 1-6
Wiring Alarm Button and Signal harnesses for Wake on Alarm
Summary of Contents for Trooper TL2
Page 1: ...Manual Type DVR Firmware Version 2 0 Document Part Number 700 0099 R008 700 0099...
Page 33: ...DVR Setup 700 0099 R008 2 17...
Page 34: ...DVR Setup 2 18 700 0099 R008...
Page 50: ...Advanced Setup 3 16 700 0099 R008...
Page 76: ...DVR Configuration Menus 4 26 700 0099 R008...
Page 78: ...L 2...
Page 82: ...Seon Design Inc Product Warranty W 4 700 0099 R008...
Page 83: ......