16
OPERATION AND USE
Continued from previous page.
This will slow down the tick and allow the operator to find a higher
concentration using the same procedure. If the tick goes away you have
moved away from the leak or there is no more gas present.
For best results always use the leak detector prior to using any liquid
leak detection fluids as these sensors will detect their presence.
10. At any time the operator may save the readings on the display by
pressing the SAVE/ZERO button (C). This will save all readings for
download at a later time.
The memory is factory set to store 6 events. This can be adjusted from
1-100 at the factory. The most recent save is first during download.
11. Following Federal, State, Municipal and/or Company procedures
move to the areas where gas readings are suspected or must be tested.
During sampling the respective readings may change. Audible and
visual alarms will activate when the preset limits are reached.
12. When being used in dark areas an automatic backlight will illuminate
the display.
13. To turn instrument off, press and hold the POWER/MUTE button (A)
for 5-6 seconds until POWER DOWN appears on the display.
1.888.610.7664
SENS