GENERAL DESCRIPTION
The
SENSIT® HXG-3
is designed to detect combustible gases. All
SENSIT® HXG-3
instruments incorporate an advanced low power
semiconductor sensor to measure combustible gases in LEL (Lower
Explosive Limit) range.
LEL resolution can be factory set between 0.1% and 2%. The ppm display
is simultaneously shown in 1 or 10ppm increments (resolution). If enabled,
the peak reading display takes precedence over the ppm display.
An automatically backlit display shows all gas concentrations being
measured. LEDs located on the front of the instrument indicate preset
visual warnings of increased gas concentration.
Audible and visual alarms warn the operator of hazardous conditions
being sensed. The preset alarms are indicated by a red flashing LED,
display indicator and alarm sound. The combustible gas alarm is preset
from 50% LEL (2.5% methane or 0.75% pentane).
The
SENSIT® HXG-3
instrument is approved by Underwriters
Laboratories to UL913, for Class 1, Division 1, Groups C & D hazardous
locations when used with Duracell™ MN1400BK or equivalent alkaline
batteries.
6
1.888.610.7664
SENS
IT