31
FACTORY ADjUSTABLE FEATURES
(Factory Only)
FEATURE
Session Saves
Alarm - LEL
PPM Display Option
Cal Due interval
Show Session Log*
Warm-up Time
Purge Time
LEL Resolution
Peak Reading
*Can be disabled
RANGE
1-100
0-100%
1ppm or 10ppm
30, 45, 60, 90, 180, 360 Days
1-100
10-30 sec.
1-60 sec.
0.1% - 2%
N/A
DEFAULT
6
50%
10ppm
30 Days
6
30 sec.
0 sec.
0.1%
Off
1.888.610.7664
SENS
IT