12
BATTERY INSTALLATION/REPLACEMENT
⚠
CAUTION: Always change batteries in an environment free of
combustible gases.
Battery replacement is necessary when the display reads BAT LOW,
an audible alarm sounds and the green ready LED flashes. When the
instrument remains in BAT LOW, a countdown will appear starting at 300
seconds (5 minutes) which is the maximum time remaining to shutdown.
Remove the battery sleeve cover by depressing the locking tab on the
front of the handle with a coin or flat object and pulling the handle away
from the top or display area of the instrument.
Place 3 approved batteries into the battery holder. For best results hold
the battery compartment so that it lays in one hand. With the other hand
install the battery that goes toward the front first, the battery that is in
contact with the rear spring second and finally insert the third battery in
the center by forcing the second battery such that the spring compresses
and allows the batteries to go into place.
If you do not use your hand to hold the bottom of the battery compartment
the batteries can come out. Observe the polarity markings on the inside
of the battery holder. Improper installation will cause the instrument not
to operate. Replace the battery sleeve and allow the locking tab to snap
into position.
NOTE:
Improper battery installation will disable the instrument.
Check to be sure the handle is secure to the instrument body by gently
pulling the handle away. The handle will remain firmly in place if a proper
connection is made.